I-procalcitonin ye-procalcitonin yokuhlola okusheshayo amadivayisi wokuhlola ilebhu ye-POCT Reagent

incazelo emfushane:

Inombolo Yemodeli I-PCT Ukupakisha 25 Ukuhlolwa/ikhithi, 20kits/CTN
Igama Ikhithi yokuxilonga ye-Procalcitonin(Fluorescence Immuno Assay) Ukuhlukaniswa kwezinsimbi Ikilasi II
Izici Ukuzwela okuphezulu, ukusebenza okulula Isitifiketi CE/ ISO13485
Isifanekiso I-Serum, i-Plasma Impilo yeshelufu Iminyaka Emibili
Ukunemba > 99% Ubuchwepheshe Ikhithi yobuningi
Isitoreji 2′C-30′C Uhlobo Izinsiza Zokuhlaziya I-Pathological


  • Isikhathi sokuhlola:10-15 imizuzu
  • Isikhathi esivumelekile:Izinyanga ezingama-24
  • Ukunemba:Ngaphezu kuka-99%
  • Ukucaciswa:1/25 ukuhlolwa/ibhokisi
  • Izinga lokushisa lesitoreji :2℃-30℃
  • Imininingwane Yomkhiqizo

    Omaka bomkhiqizo

    Imikhiqizo Imingcele

    3
    4-(3)
    4-(4)

    ISIMISO NENKQUBO YOKUHLOLA I-FOB

    ISIMISO

    I-membrane yedivayisi yokuhlola ihlanganiswe ne-anti-PCT antibody endaweni yokuhlola kanye ne-anti-rabbit IgG ye-IgG yembuzi endaweni yokulawula. Iphedi elilebula limbozwa nge-fluorescence ebhalwe ukuthi anti-PCT antibody kanye ne-rabbit IgG kusengaphambili. Lapho kuhlolwa isampula elihle, i-antigen ye-PCT kusampula ihlangana ne-fluorescence ebhalwe ukuthi i-anti PCT antibody, bese yenza ingxube yokuzivikela komzimba. Ngaphansi kwesenzo se-immunochromatography, ukugeleza okuyinkimbinkimbi ekuqondeni kwephepha elimuncayo, lapho inkimbinkimbi idlula isifunda sokuhlola, ihlangene ne-anti-PCT yokuhlanganisa i-antibody, yakha inkimbinkimbi entsha. Izinga le-PCT lihlotshaniswa kahle nesignali ye-fluorescence, futhi ukugxila kwe-PCT kusampula kungatholwa nge-fluorescence immunoassay assay.

    Inqubo Yokuhlola

    Sicela ufunde imanuwali yokusebenza kwezinsimbi kanye nokufakwa kwephakheji ngaphambi kokuhlola.

    1. Beka eceleni wonke ama-reagents namasampuli ekamelweni lokushisa.
    2. Vula i-Portable Immune Analyzer(WIZ-A101), faka ukungena ngemvume kwephasiwedi ye-akhawunti ngokwendlela yokusebenza yensimbi, bese ufaka isixhumi esibonakalayo sokubona.
    3. Skena ikhodi yokuhlonza ukuze uqinisekise into yokuhlola.
    4. Khipha ikhadi lokuhlola esikhwameni se-foil.
    5. Faka ikhadi lokuhlola endaweni yekhadi, skena ikhodi ye-QR, bese unquma into yokuhlola.
    6. Engeza i-serum engu-60μL noma isampula ye-plasma kusampuli ye-diluent, bese uxuba kahle.
    7. Engeza isisombululo sesampula esingu-80μL ukuze uthole isampula yomthombo wekhadi.
    8. Chofoza inkinobho ethi "ukuhlolwa okujwayelekile", ngemva kwemizuzu engu-15, ithuluzi lizothola ngokuzenzakalelayo ikhadi lokuhlola, lingakwazi ukufunda imiphumela esikrinini sokubonisa sensimbi, futhi lirekhode/liphrinte imiphumela yokuhlolwa.
    9. Bheka imiyalelo ye-Portable Immune Analyzer(WIZ-A101).

    ukupakisha

    Mayelana NATHI

    贝尔森主图_conew1

    I-Xiamen Baysen Medical Tech limited iyibhizinisi eliphakeme lebhayoloji elizinikela ekufakweni kwe-reagent yokuxilonga esheshayo futhi ehlanganisa ucwaningo nentuthuko, ukukhiqiza nokudayisa kukonke. Kunezisebenzi eziningi ezithuthukile zocwaningo nabaphathi bezokuthengisa enkampanini, bonke banokuhlangenwe nakho okucebile kokusebenza e-china kanye nebhizinisi lamazwe ngamazwe le-biopharmaceutical.