Amadivayisi wokuhlola we-ProCALLCITONIN ADDLELA WAMA-POCT realent

Incazelo emfushane:

Inombolo yemodeli I-ty Ukufaka ndawonye Izivivinyo ezingama-25 / kit, 20Kits / CTN
Ibizo I-Diagnostic Kit ye-ProCalcitonin(Fleorencence immuno assay) Ukuhlukaniswa Kwensimbi Iklasi II
Izici Ukuzwela okuphezulu, ukuvakasha okulula Isitifiketi Ce / iso13485
Isifanekiso I-serum, i-plasma Impilo yeshelufu Iminyaka emibili
Ukuqonda nqo > 99% Ubuchwepheshe Ikhithi yenani
Ukubeka 2'c-30'c Ukuthayipha Izinsiza zokuhlaziya ze-pathological


  • Isikhathi sokuhlola:Imizuzu engu-10-15
  • Isikhathi esivumelekile:Inyanga engu-24
  • Ukunemba:Bangaphezu kuka-99%
  • Ukucaciswa:1/25 Ukuhlolwa / Ibhokisi
  • Ukushisa kwesitoreji:2 ℃ -30 ℃
  • Imininingwane Yomkhiqizo

    Amathegi Omkhiqizo

    Imikhiqizo yemikhiqizo

    +
    4- (3)
    4- (4)

    Umgomo kanye nenqubo yokuhlolwa kwe-FOB

    Isimiso

    Ulwelwesi lwedivayisi yokuhlola luhlanganiswe ne-anti PCT antibody kwisifunda sokuhlola kanye nembuzi anti Unogwaja I-IGG antibody on the control. I-Lable Pad ihlanganiswe yi-fluorescence ilebula anti PCT antibody kanye noRabbit IGG kusengaphambili. Lapho uvivinya isampula eline-PCT, i-PCT Antigen yesampula ihlangana ne-fluorescence ilebula anti-pct antibody, bese wenza umxube wokuzivikela. Ngaphansi kwesenzo se-Immunochrotography, ukugeleza okuyinkimbinkimbi kokuqondiswa kwephepha lokumunca, lapho kuyinkimbinkimbi edlula esifundeni sokuhlola, kuhlanganiswe ne-anti PCT ehlanganisiwe i-antilody, amafomu amasha. Izinga le-PCT lixhumeka kahle ngesiginali ye-fluorescence, kanye nokuqoqwa kwe-PCT kwisampula yesampula kungatholwa yi-fluorence iMmunoassay Assay.

    Inqubo yokuhlola

    Uyacelwa ukuthi ufunde incwadi yokusebenza kwensimbi yokusebenza kwensimbi kanye nokufaka iphakheji ngaphambi kokuhlolwa.

    1. Beka eceleni yonke imiphenduli namasampula wokushisa kwegumbi.
    2. Vula i-Immune Analyzer ye-Immunezer (Wiz-A101), faka ukungena kwephasiwedi ye-akhawunti ngokuya ngendlela yokusebenza yensimbi, bese ufaka isikhombimsebenzisi sokuthola.
    3. Skena ikhodi yamazinyo ukuze uqinisekise into yokuhlola.
    4. Thatha ikhadi lokuhlola esikhwameni se-foil.
    5 Faka ikhadi lokuhlola ku-slot yekhadi, scan ikhodi ye-QR, bese unquma into yokuhlola.
    6. Faka i-60μL serum noma isampula ye-plasma kwi-dilount esampule, uhlanganise kahle.
    7. Faka isixazululo sesampuli esingu-80μL ukuze isampula kahle ekhadini.
    8. Chofoza inkinobho ethi "Ukuhlolwa Okujwayelekile", ngemuva kwemizuzu engu-15, ithuluzi lizobona ngokuzenzakalelayo ikhadi lokuhlola, lingafunda imiphumela kusuka esikrinini sokubonisa sensimbi, bese uqopha / phrinta imiphumela yokuhlola.
    9. Bheka imiyalo ye-Immune Analyzer ephathekayo (Wiz-A101).

    ukufaka ndawonye

    Mayelana NATHI

    贝尔森主图 _conew1

    I-Xiamen Baysen Medical Tech Limited ibhizinisi eliphakeme kakhulu lemvelo elizinikele lifakwe i-realegent esheshayo futhi lihlanganise ucwaningo kanye nentuthuko, ukukhiqizwa kanye nokuthengisa kukho konke. Kunabasebenzi abaningi abacwaningisi abacwaninga nabathengisi benkampani, bonke banokuhlangenwe nakho okucebile kokusebenza eChina nasebhizinisini lamazwe omhlaba.