I-HCV esheshayo yokuhlola ikhithi eyodwa yesinyathelo se-hepatitis C Virus antibody rapitor test test

Incazelo emfushane:

Inombolo yemodeli I-HCV Ukufaka ndawonye Izivivinyo ezingama-25 / kit
Ibizo Ukuxilongwa Kit Hepatitis C Virus antibody Ukuhlukaniswa Kwensimbi Iklasi II
Izici Ukuzwela okuphezulu Isitifiketi Ce / iso13485
Isifanekiso izindunduma Impilo yeshelufu Iminyaka emibili
Ukuqonda nqo > 99% Ubuchwepheshe Ikhithi yenani
Ukubeka 2'c-30'c Ukuthayipha Izinsiza zokuhlaziya ze-pathological


  • Isikhathi sokuhlola:Imizuzu engu-10-15
  • Isikhathi esivumelekile:Inyanga engu-24
  • Ukunemba:Bangaphezu kuka-99%
  • Ukucaciswa:1/25 Ukuhlolwa / Ibhokisi
  • Ukushisa kwesitoreji:2 ℃ -30 ℃
  • Imininingwane Yomkhiqizo

    Amathegi Omkhiqizo

    Imikhiqizo yemikhiqizo

    I-3HBA1C
    4- (3)
    4- (4)

    Umgomo kanye nenqubo yokuhlolwa kwe-FOB

    Isimiso

    Ulwelwesi lwedivaysi yokuhlola luhlanganiswe ne-HCV Antigen esifundeni sokuhlola kanye nembuzi anti Unogwaja IGG Antibody on the Control Region. I-Lable Pad ihlanganiswe yi-fluorescence ilebula i-HCV Antigen ne-Igg Rabbit kusengaphambili. Lapho uhlola isampula elinethemba, i-antimv ye-HCV in isampula hlanganisa ne-fluorescence ilebula i-HCV Antigen, bese wenza ingxube yobusuku bokuzivikela. Ngaphansi kwesenzo se-Immunochrotography, ukugeleza okuyinkimbinkimbi kokuqondisa kwephepha lokumunca, lapho kudlule isikhathi sokuhlola, kuhlanganiswe ne-HCV antigen coatigen antigen, amafomu amasha acwebile.hcv antibody axhumeka kahle nesiginali ye-fluorescence, kanye nokuhlushwa kwe I-antibody ye-HCV in isampula ingatholwa yi-fluorencem immunoassay assay

    Inqubo yokuhlola:

    Uyacelwa ukuthi ufunde incwadi yokusebenza kwensimbi yokusebenza kwensimbi kanye nokufaka iphakheji ngaphambi kokuhlolwa.

    1. Beka eceleni yonke imiphenduli namasampula wokushisa kwegumbi.
    2. Vula i-Immune Analyzer ye-Immunezer (Wiz-A101), faka ukungena kwephasiwedi ye-akhawunti ngokuya ngendlela yokusebenza yensimbi, bese ufaka isikhombimsebenzisi sokuthola.
    3. Skena ikhodi yamazinyo ukuze uqinisekise into yokuhlola.
    4. Thatha ikhadi lokuhlola esikhwameni se-foil.
    5 Faka ikhadi lokuhlola ku-slot yekhadi, scan ikhodi ye-QR, bese unquma into yokuhlola.
    I-6. Faka i-10μL serum noma isampula ye-plasma ibe yi-dilount esampule, futhi uhlanganise kahle ..
    7. Faka isixazululo sesampuli esingu-80μL ukuze isampula kahle ekhadini.
    8. Chofoza inkinobho ethi "Ukuhlolwa Okujwayelekile", ngemuva kwemizuzu engu-15, ithuluzi lizobona ngokuzenzakalelayo ikhadi lokuhlola, lingafunda imiphumela kusuka esikrinini sokubonisa sensimbi, bese uqopha / phrinta imiphumela yokuhlola.
    9. Bheka imiyalo ye-Immune Analyzer ephathekayo (Wiz-A101).

    ukufaka ndawonye

    Mayelana NATHI

    贝尔森主图 _conew1

    I-Xiamen Baysen Medical Tech Limited ibhizinisi eliphakeme kakhulu lemvelo elizinikele lifakwe i-realegent esheshayo futhi lihlanganise ucwaningo kanye nentuthuko, ukukhiqizwa kanye nokuthengisa kukho konke. Kunabasebenzi abaningi abacwaningisi abacwaninga nabathengisi benkampani, bonke banokuhlangenwe nakho okucebile kokusebenza eChina nasebhizinisini lamazwe omhlaba.