Ikhithi yokuhlola esheshayo ye-HbA1C I-Glycosylated hemoglobin A1c Test Kit IVD ikhithi yokuhlola ngokushesha

incazelo emfushane:

Inombolo Yemodeli I-HbA1c Ukupakisha 25 Izivivinyo/ikhithi
Igama Ikhithi Yokuhlola I-Glycosylated Hemoglobin A1c Ukuhlukaniswa kwezinsimbi Ikilasi II
Izici Ukuzwela okuphezulu, ukusebenza okulula Isitifiketi CE/ ISO13485
Isifanekiso indle Impilo yeshelufu Iminyaka Emibili
Ukunemba > 99% Ubuchwepheshe Ikhithi yobuningi
Isitoreji 2′C-30′C Uhlobo Izinsiza Zokuhlaziya I-Pathological


  • Isikhathi sokuhlola:10-15 imizuzu
  • Isikhathi esivumelekile:Izinyanga ezingama-24
  • Ukunemba:Ngaphezu kuka-99%
  • Ukucaciswa:1/25 ukuhlolwa/ibhokisi
  • Izinga lokushisa lesitoreji :2℃-30℃
  • Imininingwane Yomkhiqizo

    Omaka bomkhiqizo

    Imikhiqizo Imingcele

    3Hba1c
    4-(2)
    4-(1)

    ISIMISO NENKQUBO YOKUHLOLA I-FOB

    ISIMISO

    Ulwelwesi lwedivayisi yokuhlola lumbozwe nge-anti-HbA1c antibody endaweni yokuhlola kanye ne-anti-Hb antibody endaweni yokulawula. Iphedi elilebula limbozwa nge-fluorescence ebhalwe ukuthi i-anti-Hb antibody kanye ne-anti-HbA1c antibody kusengaphambili. Lapho kuhlolwa isampula, i-antigen ye-HbA1c kusampula ihlangana ne-fluorescence ebhalwe ukuthi i-anti-HbA1c antibody, i-antigen ye-Hb esesampula ihlanganisa ne-fluorescence enelebuli ye-anti Hb antibody futhi yakhe ingxube yamasosha omzimba. Ngaphansi kwesenzo se-immunochromatography, ukugeleza okuyinkimbinkimbi kubheke ephepheni elimuncayo, lapho inkimbinkimbi idlula isifunda sokuhlola, ihlangene ne-anti-HbA1c yokuhlanganisa i-antibody, yakha inkimbinkimbi entsha. lapho inkimbinkimbi idlula isifunda sokulawula, ihlangene ne-anti-Hb coating antibody, yakha inkimbinkimbi entsha.Izinga le-HbA1c lihlotshaniswa kahle nesignali ye-fluorescence, futhi ukugxila kwe-HbA1c ne-Hb kusampula kungatholwa nge-fluorescence immunoassay assay.

    Inqubo Yokuhlola:

    Sicela ufunde imanuwali yokusebenza kwezinsimbi kanye nokufakwa kwephakheji ngaphambi kokuhlola.

    1. Beka eceleni wonke ama-reagents namasampuli ekamelweni lokushisa.
    2. Vula i-Portable Immune Analyzer(WIZ-A101), faka ukungena ngemvume kwephasiwedi ye-akhawunti ngokwendlela yokusebenza yensimbi, bese ufaka isixhumi esibonakalayo sokubona.
    3. Skena ikhodi yokuhlonza ukuze uqinisekise into yokuhlola.
    4. Khipha ikhadi lokuhlola esikhwameni se-foil.
    5. Faka ikhadi lokuhlola endaweni yekhadi, skena ikhodi ye-QR, bese unquma into yokuhlola
    6. Faka i-10μL Igazi eliphelele kwisampula ye-diluent, nyakazisa iminithi elingu-1 bese uxuba kahle.
    7. Engeza isisombululo sesampula esingu-80μL ukuze uthole isampula yomthombo wekhadi.
    8. Chofoza inkinobho ethi "ukuhlolwa okujwayelekile", ngemva kwemizuzu engu-15, ithuluzi lizothola ngokuzenzakalelayo ikhadi lokuhlola, lingakwazi ukufunda imiphumela esikrinini sokubonisa sensimbi, futhi lirekhode/liphrinte imiphumela yokuhlolwa.
    9. Bheka imiyalelo ye-Portable Immune Analyzer(WIZ-A101).

    ukupakisha

    Mayelana NATHI

    贝尔森主图_conew1

    I-Xiamen Baysen Medical Tech limited iyibhizinisi eliphakeme lebhayoloji elizinikela ekufakweni kwe-reagent yokuxilonga esheshayo futhi ehlanganisa ucwaningo nentuthuko, ukukhiqiza nokudayisa kukonke. Kunezisebenzi eziningi ezithuthukile zocwaningo nabaphathi bezokuthengisa enkampanini, bonke banokuhlangenwe nakho okucebile kokusebenza e-china kanye nebhizinisi lamazwe ngamazwe le-biopharmaceutical.

    Isibonisi sesitifiketi

    dxgrd

  • Okwedlule:
  • Olandelayo: