I-HBA1C ngokushesha kit i-Glycosyyled HemogloByyled Hemoglobin A1C Test Kit IVD Ukuhlola Ukuhlola

Incazelo emfushane:

Inombolo yemodeli HBA1C Ukufaka ndawonye Izivivinyo ezingama-25 / kit
Ibizo Ukuxilongwa Kit Glycosylated Hemoglobin A1C Ukuhlukaniswa Kwensimbi Iklasi II
Izici Ukuzwela okuphezulu, ukuvakasha okulula Isitifiketi Ce / iso13485
Isifanekiso izindunduma Impilo yeshelufu Iminyaka emibili
Ukuqonda nqo > 99% Ubuchwepheshe Ikhithi yenani
Ukubeka 2'c-30'c Ukuthayipha Izinsiza zokuhlaziya ze-pathological


  • Isikhathi sokuhlola:Imizuzu engu-10-15
  • Isikhathi esivumelekile:Inyanga engu-24
  • Ukunemba:Bangaphezu kuka-99%
  • Ukucaciswa:1/25 Ukuhlolwa / Ibhokisi
  • Ukushisa kwesitoreji:2 ℃ -30 ℃
  • Imininingwane Yomkhiqizo

    Amathegi Omkhiqizo

    Imikhiqizo yemikhiqizo

    I-3HBA1C
    4- (2)
    4- (1)

    Umgomo kanye nenqubo yokuhlolwa kwe-FOB

    Isimiso

    Ulwelwesi lwedivayisi yokuhlola luhlanganiswe ne-Anti HBA1C antibody kwisifunda sokuhlola kanye ne-anti HB antibody kwisifunda sokulawula. I-LAble Pad ihlanganiswe yi-fluorescence ilebula anti HB antibody kanye ne-anti HBA1C antibody ngaphambi kwesikhathi. Lapho uhlola isampula, i-HBA1C Antigen yesampula ihlangana ne-Fluorescence ilebula anti HBA1C antibod, i-HB Antigen in Sampula ehlanganisa i-Fluorescence ilebula eli-anti Ngaphansi kwesenzo se-Immunochrotography, ukugeleza okuyinkimbinkimbi kokuqondiswa kwephepha lokumunca, lapho kuyinkimbinkimbi kudlula esifundeni sokuhlola, kuhlanganiswe ne-anti HBA1c coating coating antilody, amafomu amasha abucayi. Lapho kuyinkimbinkimbi edlula esifundeni sokulawula, kuhlangene ne-anti HB coating antiating antiation, amazinga amasha acwebile.hba1c axhumeka kahle ngesiginali ye-fluorescence, kanye ne-HB1C ne-HB ngesampula kungatholwa yi-fluorescence immunoassay Assay.

    Inqubo yokuhlola:

    Uyacelwa ukuthi ufunde incwadi yokusebenza kwensimbi yokusebenza kwensimbi kanye nokufaka iphakheji ngaphambi kokuhlolwa.

    1. Beka eceleni yonke imiphenduli namasampula wokushisa kwegumbi.
    2. Vula i-Immune Analyzer ye-Immunezer (Wiz-A101), faka ukungena kwephasiwedi ye-akhawunti ngokuya ngendlela yokusebenza yensimbi, bese ufaka isikhombimsebenzisi sokuthola.
    3. Skena ikhodi yamazinyo ukuze uqinisekise into yokuhlola.
    4. Thatha ikhadi lokuhlola esikhwameni se-foil.
    5. Faka ikhadi lokuhlola ku-slot yekhadi, scan ikhodi ye-QR, bese unquma into yokuhlola
    6. Faka i-10μL igazi lonke kwi-tamputa ecwebezelayo, unikine 1 min uhlanganise kahle.
    7. Faka isixazululo sesampuli esingu-80μL ukuze isampula kahle ekhadini.
    8. Chofoza inkinobho ethi "Ukuhlolwa Okujwayelekile", ngemuva kwemizuzu engu-15, ithuluzi lizobona ngokuzenzakalelayo ikhadi lokuhlola, lingafunda imiphumela kusuka esikrinini sokubonisa sensimbi, bese uqopha / phrinta imiphumela yokuhlola.
    9. Bheka imiyalo ye-Immune Analyzer ephathekayo (Wiz-A101).

    ukufaka ndawonye

    Mayelana NATHI

    贝尔森主图 _conew1

    I-Xiamen Baysen Medical Tech Limited ibhizinisi eliphakeme kakhulu lemvelo elizinikele lifakwe i-realegent esheshayo futhi lihlanganise ucwaningo kanye nentuthuko, ukukhiqizwa kanye nokuthengisa kukho konke. Kunabasebenzi abaningi abacwaningisi abacwaninga nabathengisi benkampani, bonke banokuhlangenwe nakho okucebile kokusebenza eChina nasebhizinisini lamazwe omhlaba.