ukunemba okuphezulu kwe-PRL ukuhlolwa okusheshayo Imichilo yokuhlola ye-pituitary prolactin

incazelo emfushane:

Inombolo Yemodeli I-PRL Ukupakisha 25 Ukuhlolwa/ikhithi, 20kits/CTN
Igama Ikhithi yokuxilonga yokuhlola okusheshayo kwe-PRL I-Pituitary prolactin(i-Fluorescence Immuno Assay) Ukuhlukaniswa kwezinsimbi Ikilasi II
Izici Ukuzwela okuphezulu, ukusebenza okulula Isitifiketi CE/ ISO13485
Isifanekiso I-Serum, i-Plasma Impilo yeshelufu Iminyaka Emibili
Ukunemba > 99% Ubuchwepheshe Ikhithi ye-quantitative
Isitoreji 2′C-30′C Uhlobo Izinsiza Zokuhlaziya I-Pathological


  • Isikhathi sokuhlola:10-15 imizuzu
  • Isikhathi esivumelekile:Izinyanga ezingama-24
  • Ukunemba:Ngaphezu kuka-99%
  • Ukucaciswa:1/25 ukuhlolwa/ibhokisi
  • Izinga lokushisa lesitoreji :2℃-30℃
  • Imininingwane Yomkhiqizo

    Omaka bomkhiqizo

    Incwajana ye-FOB

    3.PRL
    4 (1)
    4 (2)

    ISIMISO NENKQUBO YOKUHLOLA I-FOB

    Isimiso:

    Umucu une-anti-FOB enamathela amasosha omzimba endaweni yokuhlola, eboshelwe ku-membrane chromatography kusengaphambili. Iphedi elebula limbozwe i-fluorescence ebhalwe ukuthi i-anti-FOB antibody kusengaphambili. Lapho kuhlolwa isampula elihle, i-FOB kusampula ingaxutshwa ne-fluorescence ebhalwe ukuthi i-anti-FOB antibody, futhi yakhe inhlanganisela yokuzivikela komzimba. Njengoba ingxube ivunyelwa ukuthi ithuthe eduze komugqa wokuhlola, inkimbinkimbi ye-FOB conjugate ithathwa yi-anti-FOB enamathela kuma-antibody kulwelwesi futhi yakha inkimbinkimbi. Amandla e-fluorescence ahlotshaniswa kahle nokuqukethwe kwe-FOB. I-FOB esesampula ingatholwa nge-fluorescence immunoassay analyzer.

    Inqubo Yokuhlola:

    1.Beka eceleni wonke ama-reagents namasampuli ekamelweni lokushisa.
    2.Vula i-Portable Immune Analyzer(WIZ-A101), faka ukungena ngemvume kwephasiwedi ye-akhawunti ngokwendlela yokusebenza yethuluzi, bese ufaka isixhumi esibonakalayo sokubona.
    3.Skena ikhodi yokuhlonza ukuze uqinisekise into yokuhlola.
    4.Khipha ikhadi lokuhlola esikhwameni se-foil.
    5.Faka ikhadi lokuhlola endaweni yekhadi, skena ikhodi ye-QR, bese unquma into yokuhlola.
    6.Khipha ikepisi kushubhu yesampula bese ulahla amathonsi amabili okuqala esampula ehlanjululiwe, engeza amaconsi ama-3 (cishe u-100uL) alikho ibhamuza elihlanjululwe isampula lime mpo futhi kancane ungene emthonjeni wesampula wekhadi eline-dispette enikeziwe.
    7.Chofoza inkinobho ethi "standard test", ngemva kwemizuzu engu-15, ithuluzi lizobona ngokuzenzakalelayo ikhadi lokuhlola, lingakwazi ukufunda imiphumela esikrinini sokubonisa sensimbi, futhi lirekhode/liphrinte imiphumela yokuhlolwa.
    8.Bheka umyalelo we-Portable Immune Analyzer(WIZ-A101).

    ukupakisha

    Ungase uthande

    Ikhithi Yokuxilongwa YeHormone Evuselela I-Follicle (I-Fluorescence Immunochromatographic Assay)

    Mayelana NATHI

    贝尔森主图_conew1

    I-Xiamen Baysen Medical Tech limited iyibhizinisi eliphakeme lebhayoloji elizinikela ekufakweni kwe-reagent yokuxilonga esheshayo futhi ehlanganisa ucwaningo nentuthuko, ukukhiqiza nokudayisa kukonke. Kunezisebenzi eziningi ezithuthukile zocwaningo nabaphathi bezokuthengisa enkampanini, bonke banokuhlangenwe nakho okucebile kokusebenza e-china kanye nebhizinisi lamazwe ngamazwe le-biopharmaceutical.