Ngo-2019 Price Price China China Ukukhulelwa Test Midstream 6.0mm Izinyanga ezingama-24 Izinyanga
Konke esikwenzayo kuhlale kuhlobene neklayenti lethu le-tenet "kuqala, zithembele ku-1st, zinikele mayelana nokupakishwa kokudla kanye nokuvikelwa kwemvelo kwentengo ephelele ye-2019 ChinaUkukhulelwa kuhlolwa Midstream 6.0mmIzinyanga ezingamasheya ezinyangeni ezingama-24, sinemikhiqizo efanelekile ulwazi kanye nesipiliyoni esicebile ekwenziweni. Ngokuvamile sicabanga ukuthi impumelelo yakho ibhizinisi lethu lebhizinisi!
Konke esikwenzayo kuhlale kuhlobene neklayenti lethu le-tenet "kuqala, zithembele ku-1st, zinikele ngokupakishwa kokudla kanye nokuvikelwa kwemveloAmazinga wokuzwela wokukhulelwa kweChina angama-25 MIU, Ukukhulelwa kuhlolwa Midstream 6.0mm, Imishini yethu ethuthukisiwe, ukuphathwa okuhle kakhulu, ukucwaninga kanye nekhono lokuthuthuka kwenza intengo yethu iye phansi. Intengo esiyinikezayo kungenzeka ingabi ophansi kakhulu, kepha siyakuqinisekisa ukuthi iyancintisana ngokuphelele! Uyemukelwa ukuxhumana nathi ngokushesha ebudlelwaneni bebhizinisi elizayo kanye nempumelelo evumelana ngayo!
I-Diagnostic Kit yeI-hormoneI-Fluorescence Immunochrogamographic Assay)
Ngokusetshenziswa kokuxilongwa kwe-vitro kuphela
Uyacelwa ukuthi ufunde leli phakethe Faka ngokucophelela ngaphambi kokusebenzisa futhi ulandele imiyalo ngokuqinile. Ukwethembeka kwemiphumela ye-Assay akunakuqinisekiswa uma kukhona ukuphambuka emiyalweni ekuleW kufakiwe.
Ukusetshenziswa okuhlosiwe
Ikhithi yokuxilonga ye-hormone ye-bukeni ezinye izindlela. Lokhu kuhlola kuhloselwe ukusetshenziswa kwezempilo kuphela.
Ukubeka kafushane
I-Huxinizing Hormone (LH) iyi-glycoprotein enesisindo samangqamuzana esingama-30,000 Dalton, akhiqizwa yi-pituitary engaphandle. Ukuhlushwa kwe-LH kuhlobene kakhulu ne-ovulation yama-ovari, kanti inani eliphakeme le-LH libikezelwa ukuthi libe ngamahora angama-24 kuya kwangama-36 we-ovulation. Ngakho-ke, inani eliphakeme le-LH lingabhekelwa ngesikhathi sokujikeleza kokuya esikhathini ukuthola isikhathi esifanele sokukhulelwa. Umsebenzi ongajwayelekile we-endocrine ku-pituitary gland ungadala i-LH Secreion Irractionuty.Inqolobane ye-LH ingasetshenziswa ukuhlola umsebenzi we-Putaitary Endocrine. Ikhithi yokuxilonga isuselwe ku-Immunochrotography futhi inganikeza umphumela kungakapheli imizuzu eyi-15.
Umgomo wenqubo
Ulwelwesi lwedivayisi yokuhlola luhlanganiswe ne-anti lh antilody esifundeni sokuhlola kanye nembuzi anti Unogwaja I-IGG antibody on the control. I-LAble Pad ihlanganiswe yi-fluorescence ilebula anti lh antibody kanye ne-rabbit igg kusengaphambili. Lapho uhlola isampula elimuhle, i-LH Antigen ku-Sampula ehlanganisiwe ne-Fluorescence ilebula anti lh antibody, futhi akha ingxube yomzimba. Ngaphansi kwesenzo se-Immunochrotography, ukugeleza okuyinkimbinkimbi kokuqondiswa kwephepha lokumunca, lapho kuyinkimbinkimbi kudlula esifundeni sokuhlola, kuhlanganiswe ne-anti lh coating antibod, amafomu amasha abumbana. Ileveli ye-LH ixhumeka kahle ngesiginali ye-fluorescence, kanye nokuqoqwa kwe-LH ngesampula kungatholwa yi-fluorencem immunoassay assay.
Ama-reagents nezinto zokwenziwa
25T Iphakethe Izakhi:
.Test Card ngakunye i-foil ipaniwe nge-desiccant 25t
.SAMPLE DLOLUENTES
.Fackage Faka
Izinto ezidingekayo kodwa azinikeziwe
Isithakongo esiqoqiwe sesampula, isibali sikhathi
Ukuqoqwa kwesampula nesitoreji
1.Izimpumu ezihlolwe zingaba yi-serum, i-heparin anticoaagulant plasma noma i-edta anticoaagulant plasma.
2.Faka kumasu ajwayelekile ukuqoqa isampula. Isampula ye-serum noma ye-plasma ingagcinwa esiqandisini ku-2-8 ℃ ngezinsuku eziyi-7 days kanye ne-cropressoal
I-3.all isampula igweme imijikelezo ye-freeze-thaw.
Inqubo yokufa
Inqubo yokuhlola ithuluzi ibona incwajana ye-immunoanalyzer. Inqubo yokuhlola i-Reagent imi kanjena
1.Lay ubeka wonke ama-reagents namasampula wokushisa kwegumbi.
I-2.open them immune analyzer (Wiz-A101), faka ukungena ngemvume kwe-akhawunti ngokusho kwendlela yokusebenza yensimbi, bese ufaka isikhombimsebenzisi sokuthola.
I-3.Sc Ikhodi Yokucacisa Ukuqinisekisa Into Yokuhlola.
4.Thola ikhadi lokuhlola esikhwameni se-foil.
5.Shuma ikhadi lokuhlola ekhadini lekhadi, scan ikhodi ye-QR, bese unquma into yokuhlola.
I-6.Add 20μL serum noma isampula ye-plasma ukuze isampula isampula, uhlanganise kahle ..
7.ADD 80μL isixazululo isampula yesampula kahle yekhadi.
8.Chofoza inkinobho ethi "Ukuhlolwa okujwayelekile", ngemuva kwemizuzu eyi-15, ithuluzi lizobona ngokuzenzakalelayo ikhadi lokuhlola, lingafunda imiphumela kusuka esikrinini sokubonisa sensimbi, bese uqopha / phrinta imiphumela yokuhlola.
9.Refer ekufundisweni kwe-immune analyzer (Wiz-A101).
Imiphumela yokuhlola nokutolika
Isiteji | Uhla (miu / ml) | |
Owesilisa | 1.50-9.25 | |
Insikazi | Isigaba se-Follucular | 1.25-11.80 |
| isikhathi se-ovulari | 13.15-94.75 |
| Isigaba seLuteal | 1.05-14.50 |
| -Bukhosi | 7.70-64.20 |
.Imininingwane engenhla iyisikhashana esisungulwe idatha yokutholwa kwale kit, futhi kuphakanyiswa ukuthi ilabhorethri ngalinye kufanele lisungule isikhawu sokubaluleka komtholampilo.
.Ihlukelo se-LH luphakeme kunebanga lezethenjwa, futhi izinguquko zomzimba noma impendulo yokucindezela kufanele zikhishwe ngaphandle kwe-, kufanele zihlanganise ukuxilongwa kophawu lwemitholampilo.
.Imiphumela yale ndlela isebenza kuphela ebangeni lereferensi elisungulwe yile ndlela, futhi imiphumela ayiqhathaniswa ngqo nezinye izindlela.
Izici ze-.
Ukugcinwa nokuqina
I-1.Ikhithi iyizinyanga eziyi-18 zeShelf-Life kusuka ngosuku lokukhiqiza. Gcina amakhithi angasetshenziswanga ngo-2-30 ° C. Ungabazi. Ungasebenzisi ngaphezu kosuku lokuphelelwa yisikhathi.
2.Ungakuvuli esikhwameni esivaliwe uze ulungele ukwenza isivivinyo, futhi ukuhlolwa okusetshenziswa okukodwa kuphakanyiswa ukuthi kusetshenziswe ngaphansi kwendawo edingekayo (lokushisa 2-35 ℃, umswakama we-40-90%) ngaphakathi kwamaminithi angama-60 ngokushesha ngangokunokwenzeka.
3.Sample Diloulent isetshenziswa ngokushesha ngemuva kokuvulwa.
Izexwayiso kanye nokuqapha
.Ikhithi kufanele ivalwe futhi ivikelwe kumswakama.
.Imininingwane emihle izoqinisekiswa ezinye izindlela.
.All amasampula azophathwa njengokungcoliswa okungaba khona.
.Ungasebenzisi i-reagent ephelelwe yisikhathi.
. Hhayi ukushintshana kwama-reagents phakathi kwamakhithi ane-Lot ehlukile Cha ..
.Ungasebenzisi kabusha amakhadi okuhlola nanoma yiziphi izesekeli ezilahlwayo.
.Kungani, isampula ngokweqile noma elincane lingaholela ekuphaphemeni komphumela.
LUkufanisa
.S nganoma yisiphi ama-antibodies asegulayo e-Assay asebenzisa, kungenzeka ukuthi kuphazanyiswe ngama-antibodies angomuntu alwa nobuntu (Hama) ku-specimen. Izinhlobo ezivela ezigulini ezithole amalungiselelo ama-antibodies e-monoclonal yokuxilongwa noma ukwelashwa kungaqukatha uHama. Izinhlobo ezinjalo zingadala imiphumela emibi noma engamanga.
Umphumela wokuhlola we-.Lokhuwo we-. .
.Lokhu i-realent isetshenziselwa kuphela ukuhlolwa kwe-serum ne-plasma. Kungase kungatholi umphumela onembile uma usetshenziselwa amanye amasampula anjenge-saliva nomchamo nokunye.
Izici Zokusebenza
Ubunoriti | I-10miu / ml kuya ku-10000miu / ml | Ukuphambuka okuhlobene: -15% kuya ku-15%. |
I-Linear colloeffection coefflication: (R) ≥0.9900 | ||
Ukuqonda nqo | Izinga lokutakula lizoba ngaphakathi kwama-85% - 115%. | |
-Phindaphiwe | Cv≤15% | |
Ukucaciswa (azikho ezintweni ezihlolelekile ekuhlolweni okuphazanyiswe ku-assay) | -Thizelwayo | Ukugxila okuphazamisayo |
Hemoglobin | I-200c / mL | |
qhudelana | I-100μ / ml | |
I-Horse Radish Peroxidase | I-2000μ / ml | |
Fsh | I-200MIU / ML | |
I-HCG | 20000miu / ml | |
Tsh | I-200μiu / ml |
Ukunqubekela phambili
1.Hansen JH, et al.hama ukuphazamiseka nge-murine monoclonal antibody-based immunody [j] .j we-Clin immunoassay, 1993,16: 294-299.
I-2.levinson ss.Imvelo yama-antibophilies ama-heterophilic kanye neqhaza ekuphazanyisweni kwe-immunoassay [j] .j we-mimunoassay, 1992,15: 108-114.
Ukhiye wezimpawu ezisetshenzisiwe:
![]() | Kudivayisi yezokwelapha yokuxilongwa kwe-vitro |
![]() | Umenzi |
![]() | Gcina ngo-2-30 ℃ |
![]() | Usuku lokuphelelwa isikhathi |
![]() | Ungaphinde usebenzise kabusha |
![]() | Isiqapheliso |
![]() | Bheka imiyalo yokusebenzisa |
Xiamen Wiz Biotech Co., Ltd
Ikheli: 3-4 phansi, i-No.16 yokwakha, indawo yokusebenzela ye-bio-medical, 2030 wengjiao West Road, Haicang District, 3610266, xiamen, China
I-TELE: + 86-592-6808278
Ifeksi: + 86-592-6808279