Reliable Supplier Transferrin Test Strips - home test one step Rotavirus Group A test kit latex RV test IVD reagent – Baysen

short description:


Product Detail

Product Tags

Related Video

Feedback (2)

"Control the quality by the details, show the power by quality". Our enterprise has strived to establish a remarkably efficient and stable team team and explored an effective excellent control system for Cea Rapid Test Kit , Digestive Tract Test Kit , Calprotectin , As a result of our hard perform, we have always been around the forefront of clean technology merchandise innovation. We've been a eco-friendly partner you can rely on. Get hold of us today for additional data!
Reliable Supplier Transferrin Test Strips - home test one step Rotavirus Group A test kit latex RV test IVD reagent – Baysen Detail:

Products Parameters

3.RV-2

PRINCIPLE AND PROCEDURE OF FOB TEST

PRINCIPLE

The membrane of the test device is coated with Rotavirus Group A antigen on the test region and goat anti rabbit IgG antibody on the control region. Lable pad are coated by fluorescence labeled anti Rotavirus Group A and rabbit IgG in advance. When testing positive sample, the RV in sample combine with fluorescence labeled anti Rotavirus Group A, and form immune mixture. Under the action of the immunochromatography, the complex flow in the direction of absorbent paper. When complex passed the test region, it combined with anti-Rotavirus Group A coating antibody, forms new complex. If it is negative, there is no Rotavirus Group A antigen in the sample, so that immune complexes cannot be formed, there will be no red line in the detection area (T). Regardless of whether group A rotavirus is present in the specimen, the latex-labeled mouse IgG is chromatographed to the quality control area (C) and captured by goat anti-mouse IgG antibody. A red line will appear in the quality control area (C). The red line is the standard appears in the quality control area (C) for judging whether there are enough samples and whether the chromatography process is normal. It is also used as an internal control standard for reagents.

Test Procedure:

1.Symptomatic patients should be collected. According to reports, the maximum excretion of rotavirus in the faeces of patients with gastroenteritis occurs 3-5 days after the begin of the disease and 3-13 days after the start of symptoms. If the sample is collected long after the diarrhea, the number of antigens may not be enough to occur the positive reaction.

2.The samples should be collected in a clean, dry, waterproof container which does not contain detergents and preservatives.

3.For non-diarrhea patients, the collected faeces samples should not be less than 1-2 grams. For patients with diarrhea, if the faeces is liquid, please collect at least 1-2 ml of faeces liquid. If the faeces contains a lot of blood and mucus, please collect the sample again.

4.It is recommended to test the samples immediately after collection, otherwise they should be sent to the laboratory within 6 hours and stored at 2-8°C. If the samples have not been tested within 72 hours, they should be stored at the temperature below -15°C.

5.Use fresh feces for testing, and faeces samples mixed with diluent or distilled water

packing

You May like


Home used SARS-CoV-2 Antigen Rapid Test(Colloidal Gold)


SARS-CoV-2 Antigen Rapid Test(Colloidal Gold)


WIZ-A101 Portable Immune Analyzer


WIZ-A101 Portable Immune Analyzer


HP-Ab-3


Diagnostic Kit for Helicobacter pylori Antibody (Colloidal Gold)

About Us

贝尔森主图_conew1

Xiamen Baysen Medical Tech limited is a high biological enterprise which devotes itself to filed of fast diagnostic reagent and integrates research and development, production and sales into a whole. There are many advanced research staffs and sales managers in the company, all of them are have rich working experience in china and international biopharmaceutical enterprise.

Certificate display

dxgrd


Product detail pictures:

Reliable Supplier Transferrin Test Strips - home test one step Rotavirus Group A test kit latex RV test IVD reagent – Baysen detail pictures

Reliable Supplier Transferrin Test Strips - home test one step Rotavirus Group A test kit latex RV test IVD reagent – Baysen detail pictures

Reliable Supplier Transferrin Test Strips - home test one step Rotavirus Group A test kit latex RV test IVD reagent – Baysen detail pictures

Reliable Supplier Transferrin Test Strips - home test one step Rotavirus Group A test kit latex RV test IVD reagent – Baysen detail pictures

Reliable Supplier Transferrin Test Strips - home test one step Rotavirus Group A test kit latex RV test IVD reagent – Baysen detail pictures


Related Product Guide:
Only Conservative Use of PSA Testing Is Cost-effective 3090D553-9492-4563-8681-AD288FA52ACE Group 2 34A8E98B-62ED-4216-98D6-E986304F4C2E | Diagnostic Kit For Isoenzyme Mb Of C Reatine Kinase
Heart Attack Diagnostics Market Worth $15.4 Billion By 2024: Grand View Research, Inc. | P24 Test Strips

"Based on domestic market and expand abroad business" is our progress strategy for Reliable Supplier Transferrin Test Strips - home test one step Rotavirus Group A test kit latex RV test IVD reagent – Baysen , The product will supply to all over the world, such as: Iran, Turkey, Wellington, Today, We are with great passion and sincerity to further fulfill our global customers' needs with good quality and design innovation. We fully welcome customers from all over the world to establish stable and mutually beneficial business relationships, to have a bright future together.
  • The supplier abide the theory of "quality the basic, trust the first and management the advanced" so that they can ensure a reliable product quality and stable customers.
    5 Stars By Hedy from Peru - 2016.09.28 18:29
    A nice supplier in this industry, after a detail and careful discussion, we reached a consensus agreement. Hope that we cooperate smoothly.
    5 Stars By Antonia from Nepal - 2016.05.02 11:33