Diagnostic Kit(Colloidal gold)for Antibody to Helicobacter Pylori
For in vitro diagnostic use only
Please read this package insert carefully prior to use and strictly follow the instructions. Reliability of assay results cannot be guaranteed if there are any deviations from the instructions in this package insert.
INTENDED USE
Diagnostic Kit(Colloidal gold)for Antibody to Helicobacter Pylori is suitable for qualitative detection of HP antibody in human blood, serum or plasma samples. This test is intended for healthcare professional use only. This reagent is used to aid the diagnosis of gastric helicobacter pylori infection.
PACKAGE SIZE
1 kit /box, 10 kits /box, 25 kits,/box, 50 kits /box.
SUMMARY
Helicobacter pylori infection and chronic gastritis, gastric ulcer, gastric adenocarcinoma, gastric mucosa associated lymphoma has the close relation, in gastritis, gastric ulcer, duodenal ulcer and gastric cancer in patients with HP infection rate of about 90%. The world health organization has put HP listed as the first kind of carcinogen, and specific risk factors for gastric cancer. HP detection is HP infection diagnosis[1]. The kit is a simple, visual semiqualitative test that detects HP in human blood, serum or plasma samples, it has high detection sensitivity and strong specificity. This kit based on colloidal gold immune chromatography analysis technology to the qualitative detection of HP antibody in whole blood, serum or plasma samples, which can give a result within 15 minutes.
ASSAY PROCEDURE
1 Take out the test card from the foil bag, put it on the level table and mark it.
2 Adding sample:
Serum and plasma: add 2 drops of serum and plasma samples to the add sample hole with plastic drip, then add 1 drop sample diluent, start timing.
Whole blood: add 3 drops of whole blood sample to the sample hole with a plastic drip, then add 1 drop sample diluent, start timing.
Fingertip whole blood: add 75µL or 3 drops of fingertip whole blood to the sample hole with a plastic drip, then add 1 drop sample diluent, start timing.
3 .The result should be read within 10-15 minutes, and it is invalid after 15 minutes.
Product detail pictures:
Related Product Guide:
Is genetic testing sophisticated enough to make PSA screening viable for mainstream use? | Cpn-Igm
Cancer doctors give new PSA testing advice for some men | Cpn-Igm
We retain bettering and perfecting our goods and service. At the same time, we perform actively to do research and enhancement for professional factory for Veterinary Immunoassay Analyzer - Diagnostic Kit(Colloidal gold)for Antibody to Helicobacter Pylori – Baysen , The product will supply to all over the world, such as: Bahrain, Grenada, Honduras, Our market share of our products and solutions has greatly increased yearly. If you are interested in any of our products or would like to discuss a custom order, make sure you feel free to contact us. We've been looking forward to forming successful business relationships with new clients around the world in the near future. We've been looking forward to your inquiry and order.
By Amelia from Greece - 2015.06.26 19:27
The goods are very perfect and the company sales manager is warmful, we will come to this company to purchase next time.
By Olivia from Comoros - 2016.05.02 18:28