Professional Design Sigelei Fuchai R7 Kit - Diagnostic kit for Microalbuminuria (Alb) – Baysen

short description:


Product Detail

Product Tags

Related Video

Feedback (2)

Normally customer-oriented, and it's our ultimate concentrate on for being not only one of the most dependable, trustable and honest supplier, but also the partner for our shoppers for Psa Test Cost , Helicobacter Pylori Test , Test Kit Cea , We welcome an prospect to do enterprise along with you and hope to have pleasure in attaching even more aspects of our items.
Professional Design Sigelei Fuchai R7 Kit - Diagnostic kit for Microalbuminuria (Alb) – Baysen Detail:

Diagnostic Kit for Urine microalbumin

(Fluorescence Immunochromatographic Assay)

For in vitro diagnostic use only

Please read this package insert carefully prior to use and strictly follow the instructions. Reliability of assay results cannot be guaranteed if there are any deviations from the instructions in this package insert.

INTENDED USE

Diagnostic Kit for Urine microalbumin (Fluorescence Immunochromatographic Assay) is suitable for the quantitative detection of microalbumin in human urine by fluorescence immunochromatographic assay, which is mainly used for the auxiliary diagnosis of kidney disease.All positive sample must be confirmed by other methodologies. This test is intended for healthcare professional use only.

SUMMARY

Microalbumin is a normal protein found in the blood and is extremely rare in urine when metabolized normally. If there’s a trace amount in the urine Albumin in more than 20 micron /mL, belongs to urinary microalbumin, if can be timely treatment, can completely repair the glomeruli, eliminate proteinuria, if not timely treatment, may enter the uremia phase.The increase of urinary microalbumin is mainly seen in diabetic nephropathy, hypertension and preeclampsia in pregnancy. The condition can be accurately diagnosed by the value of urinary microalbumin, combined with the incidence, symptoms and medical history. Early detection of urinary microalbumin is very important to prevent and delay the development of diabetic nephropathy.

PRINCIPLE OF THE PROCEDURE

The membrane of the test device is coated with ALB antigen on the test region and goat anti rabbit IgG antibody on the control region. Marker pad are coated by fluorescence mark anti ALB antibody and rabbit IgG in advance. When testing sample, ALB in sample combine with fluorescence marked anti ALB antibody, and form immune mixture. Under the action of the immunochromatography, the complex flow in the direction of absorbent paper, when complex passed the test region, The free fluorescent marker will be combined with ALB on the membrane.The concentration of ALB is negative correlation for fluorescence signal, and the concentration of ALB in sample can be detected by fluorescence immunoassay assay.

REAGENTS AND MATERIALS SUPPLIED

25T package components

Test card individually foil pouched with a desiccant 25T

Package insert 1

MATERIALS REQUIRED BUT NOT PROVIDED

Sample collection container,timer

SAMPLE COLLECTION AND STORAGE

  1. The samples tested can be urine.
  2. Fresh urine samples can be collected in a disposable clean container. It is recommended to test the urine samples immediately after collection. If the urine samples cannot be tested immediately, please store them at 2-8 , but it is recommended not to store them for more than 12 hours. Do not shake the container. If there is sediment at the bottom of the container, take supernatant for testing.
  3. All sample avoid freeze-thaw cycles.
  4. Thaw samples to room temperature before use.

Product detail pictures:

Professional Design Sigelei Fuchai R7 Kit - Diagnostic kit for Microalbuminuria (Alb) – Baysen detail pictures

Professional Design Sigelei Fuchai R7 Kit - Diagnostic kit for Microalbuminuria (Alb) – Baysen detail pictures

Professional Design Sigelei Fuchai R7 Kit - Diagnostic kit for Microalbuminuria (Alb) – Baysen detail pictures


Related Product Guide:
Many older men still getting PSA test for prostate cancer, against recommendations | Cpn-Igm
Multiplexed and portable nucleic acid detection platform with Cas13, Cas12a, and Csm6 | P24 Test Strips

With responsible good quality method, good status and excellent client services, the series of solutions produced by our company are exported to lots of countries and regions for Professional Design Sigelei Fuchai R7 Kit - Diagnostic kit for Microalbuminuria (Alb) – Baysen , The product will supply to all over the world, such as: Nigeria, Ottawa, Provence, If you need any of our products, or have other items to be produced, please send us your inquiries, samples or detailed drawings. Meanwhile, aiming to develop into an international enterprise group, we look forward to receiving offers for joint ventures and other cooperative projects.
  • Production management mechanism is completed, quality is guaranteed, high credibility and service let the cooperation is easy, perfect!
    5 Stars By Nicole from British - 2015.04.25 16:46
    This supplier's raw material quality is stable and reliable, has always been in accordance with the requirements of our company to provide the goods that quality meet our requirements.
    5 Stars By Rosemary from Puerto Rico - 2016.06.29 18:55