Online Exporter Pulse Oximeter For Babies - Diagnostic Kit(LATEX)for Rotavirus Group A and adenovirus – Baysen
Online Exporter Pulse Oximeter For Babies - Diagnostic Kit(LATEX)for Rotavirus Group A and adenovirus – Baysen Detail:
Diagnostic Kit(LATEX)for Rotavirus Group A and adenovirus
For in vitro diagnostic use only
Please read this package insert carefully prior to use and strictly follow the instructions. Reliability of assay results cannot be guaranteed if there are any deviations from the instructions in this package insert.
INTENDED USE
Diagnostic Kit(LATEX)for Rotavirus Group A and adenovirus is suitable for qualitative detection of Rotavirus Group A and adenovirus antigen in human fecal samples. This test is intended for healthcare professional use only.Meanwhile, this test is used for the clinical diagnosis of infantile diarrhea in patients with Rotavirus Group Agroup A rotavirus and adenovirus infection.
PACKAGE SIZE
1 kit /box, 10 kits /box, 25 kits,/box, 50 kits /box
SUMMARY
Rotavirus is classified as a rotavirus genus of the exenteral virus, which has a spherical shape with a diameter of about 70nm. Rotavirus contains 11 segments of double-stranded RNA. The rotavirus can be seven groups (a-g) based on antigenic differences and gene characteristics. Human infections of group A, group B and C group rotavirus have been reported Rotavirus Group A is the important cause of severe gastroenteritis in children worldwide[1-2]. Human adenoviruses (HAdVs) have 51 serotypes, which can be 6 subtypes (A~F) based on immunology and biochemistry[3]. Adenoviruses can infect respiratory,intestinal, eye, bladder, and liver, and cause epidemic spread. People with normal immunity usually develop antibodies and heal themselves. For patients or children whose immunity is suppressed, adenovirus infections can be deadly.
ASSAY PROCEDURE
1.Take out the sampling stick, inserted into the faeces sample, then put the sampling stick back, screw tight and shake well, repeat the action 3 times. Or using the sampling stick picked about 50mg faeces sample, and put in a faeces sample tube containing sample dilution, and screw tightly.
2.Use disposable pipette sampling take the thinner faeces sample from the diarrhea patient, then add 3 drops (about 100uL) to the fecal sampling tube and shake well, put aside.
3.Take out the test card from the foil bag, put it on the level table and mark it.
4.Remove the cap from the sample tube and discard the first two drops diluted sample, add 3 drops (about 100uL) no bubble diluted sample verticaly and slowly into sample well of the card with provided dispette, start timing.
5.The result should be read within 10-15 minutes, and it is invalid after 15 minutes.
Product detail pictures:
Related Product Guide:
Most news coverage on new PSA testing study acknowledged costly trade-offs | Cpn-Igm
New blood test is more accurate in predicting prostate cancer risk than PSA: IsoPSA assay can help in determining the need for prostate biopsy for patients — ScienceDaily | Psa Test Cost
Every member from our high efficiency sales team values customers' needs and business communication for Online Exporter Pulse Oximeter For Babies - Diagnostic Kit(LATEX)for Rotavirus Group A and adenovirus – Baysen , The product will supply to all over the world, such as: Suriname, Philadelphia, Leicester, We offer the great variety of products in this field. Besides, customized orders are also available. What's more, you will enjoy our excellent services. In one word, your satisfaction is guaranteed. Welcome to visit our company! For more information, please come to our website.If any further inquiries, please feel free to contact us.
By Eudora from Brunei - 2015.12.14 15:26
The company comply with the contract strict, a very reputable manufacturers, worthy a long-term cooperation.
By Amy from South Africa - 2015.12.14 15:26