Diagnostic Kit(Colloidal Gold)for Fecal Occult Blood
For in vitro diagnostic use only
Please read this package insert carefully prior to use and strictly follow the instructions. Reliability of assay results cannot be guaranteed if there are any deviations from the instructions in this package insert.
INTENDED USE
Diagnostic Kit(Colloidal Gold)for Fecal Occult Blood (FOB) is a colloidal gold immunochromatographic assay for the qualitative determination of hemoglobin in human faeces, it acts as gastrointestinal bleeding auxiliary diagnosis reagent clinical diagnosis. This test is a screening reagent. All positive sample must be confirmed by other methodologies. This test is intended for healthcare professional use only. Meanwhile, this test is used for IVD, extra instruments are not needed.
PACKAGE SIZE
1 kit /box, 10 kits /box, 25 kits,/box, 100 kits /box
SUMMARY
The slight bleeding of digestive tract disease give rise to FOB, so the detection of FOB has important value for gastrointestinal bleeding disease auxiliary diagnosis, it is available approach for screening digestive tract diseases. The kit is a simple, visual qualitative test that detects hemoglobin in human faeces, it has high detection sensitivity and strong specificity. The test is based on immunochromatography and can give a result within 15 minutes.
ASSAY PROCEDURE
1.Take out the sampling stick, inserted into the faeces sample, then put the sampling stick back, screw tight and shake well, repeat the action 3 times. Or using the sampling stick picked about 50mg faeces sample, and put in a faeces sample tube containing sample dilution, and screw tightly.
2.Use disposable pipette sampling take the thinner faeces sample from the diarrhea patient, then add 3 drops (about 100uL) to the fecal sampling tube and shake well, put aside.
3.Take out the test card from the foil bag, put it on the level table and mark it.
4Remove the cap from the sample tube and discard the first two drops diluted sample, add 3 drops (about 100uL) no bubble diluted sample verticaly and slowly into sample well of the card with provided dispette, start timing.
5.For the test strip: take out the test strip from the foil bag, put it on the level table and mark it. Dip the end with arrow of the strip into the sample solution, start timing.
6.The result should be read within 10-15 minutes, and it is invalid after 15 minutes.
Product detail pictures:
Related Product Guide:
Attention Pathologists! New Prostate Cancer Test Has CPT Code, NCCN Guideline Recommendation, and Potential Market of One Million Prostate Biopsies Annually | Diagnostic Kit For Isoenzyme Mb Of C Reatine Kinase
Quyết định 2821/QĐ-BYT 2018 Danh mục sinh phẩm chẩn đoán invitro được lưu hành | Calprotectin Elisa Kit
We pursue the management tenet of "Quality is superior, Service is supreme, Reputation is first", and will sincerely create and share success with all clients for OEM/ODM Manufacturer Ultrasonic Water Level Meter - Diagnostic Kit(Colloidal Gold)for Fecal Occult Blood – Baysen , The product will supply to all over the world, such as: Ukraine, Jersey, Mongolia, We always adhere to follow the honesty, mutual benefit, common development, after years of development and the tireless efforts of all staff, now has perfect export system, diversified logistics solutions, comprehensive meet customer shipping, air transport, international express and logistics services. Elaborate one-stop sourcing platform for our customers!
By Diego from Lahore - 2016.08.21 14:13
This supplier offers high quality but low price products, it is really a nice manufacturer and business partner.
By Joanne from Provence - 2016.08.16 13:39