OEM/ODM Factory Digestion Analyzer - Diagnostic Kit for Total Thyroxine (fluorescence immunochromatographic assay) – Baysen

short description:


Product Detail

Product Tags

Related Video

Feedback (2)

Our mission should be to turn out to be an innovative supplier of high-tech digital and communication devices by furnishing benefit added design and style, world-class manufacturing, and repair capabilities for Hp-Ab , Cea Diagnostick Kit , Chlamydia And Gonorrhea , We are not satisfied with the present achievements but we are trying best to innovate to meet buyer's more personalized needs. No matter where you are from, we are here to wait for your kind request, and welcom to visit our factory. Choose us, you can meet your reliable supplier.
OEM/ODM Factory Digestion Analyzer - Diagnostic Kit for Total Thyroxine (fluorescence immunochromatographic assay) – Baysen Detail:

Diagnostic Kit for Total Thyroxine (fluorescence immunochromatographic assay)
For in vitro diagnostic use only

Please read this package insert carefully prior to use and strictly follow the instructions. Reliability of assay results cannot be guaranteed if there are any deviations from the instructions in this package insert.

INTENDED USE
Diagnostic Kit for Total Thyroxine (fluorescence immunochromatographic assay) is a fluorescence immunochromatographic assay for the quantitative detection of Total Thyroxine (TT4) in human serum or plasma, which is mainly used to evaluate thyroid function.It is an auxiliary diagnosis reagent.All positive sample must be confirmed by other methodologies. This test is intended for healthcare professional use only.

SUMMARY
Thyroxine(T4) is secreted by the thyroid gland and its molecular weight is 777D. The total T4(Total T4,TT4) in the serum is 50 times that of the serum T3. Among them, 99.9 % of TT4 binds to serum Thyroxine Binding Proteins(TBP),and free T4(Free T4,FT4) is less than 0.05 %. T4 and T3 participate in regulating the body’s metabolic function. TT4 measurements are used to evaluate thyroid functional status and diagnosis of diseases. Clinically, TT4 is a reliable indicator for the diagnosis and efficacy observation of hyperthyroidism and hypothyroidism.

PRINCIPLE OF THE PROCEDURE
The membrane of the test device is coated with the conjugate of BSA and T4 on the test region and goat anti rabbit IgG antibody on the control region. Marker pad are coated by fluorescence mark anti T4 antibody and rabbit IgG in advance. When testing sample, TT4 in sample combine with fluorescence marked anti T4 antibody, and form immune mixture. Under the action of the immunochromatography, the complex flow in the direction of absorbent paper, when complex passed the test region, The free fluorescent marker will be combined with T4 on the membrane.The concentration of TT4 is negative correlation for fluorescence signal, and the concentration of TT4 in sample can be detected by fluorescence immunoassay assay.

REAGENTS AND MATERIALS SUPPLIED

25T package components
.Test card individually foil pouched with a desiccant 25T
.A solution 25T
.B solution 1
.Package insert 1

MATERIALS REQUIRED BUT NOT PROVIDED
Sample collection container,timer

SAMPLE COLLECTION AND STORAGE
1.The samples tested can be serum, heparin anticoagulant plasma or EDTA anticoagulant plasma.

2.According to standard techniques collect sample. Serum or plasma sample can be kept refrigerated at 2-8℃ for 7days and cryopreservation below -15°C for 6 months.
3.All sample avoid freeze-thaw cycles.

ASSAY PROCEDURE

The test procedure of the instrument see the immunoanalyzer manual. The reagent test procedure is as follows
1.Lay aside all reagents and samples to room temperature.
2.Open the Portable Immune Analyzer(WIZ-A101), enter the account password login according to the operation method of the instrument, and enter the detection interface.
3.Scan the dentification code to confirm the test item.
3.Take out the test card from the foil bag.
4.Insert the test card into the card slot, scan the QR code, and determine the test item.
5.Add 20μL serum or plasma sample to  A solution, and mix well.
6.Add 20μL B solution to the above mixture, and mix well.

Leave the mixture for 20 minutes.
Add 80μL mixture to sample well of the card.
Click the “standard test” button,after 10 minutes, the instrument will automatically detect the test card, it can read the results from the display screen of the instrument, and record/print the test results.
Refer to the instruction of Portable Immune Analyzer(WIZ-A101).

EXPECTED VALUES
TT4 normal range:55-140nmol/L

It is recommended that each laboratory establish its own normal range representing its patient population.

TEST RESULTS AND INTERPRETATION
.The above data is the reference interval established for the detection data of this kit, and it is suggested that each laboratory should establish a reference interval for the relevant clinical significance of the population in this region.

.The concentration of TT4 is higher than the reference range, and the physiological changes or stress response should be excluded.Indeed abnormal, should combine clinical symptom diagnosis.
.The results of this method are only applicable to the reference range established by this method, and the results are not directly comparable with other methods.
.Other factors can also cause errors in detection results, including technical reasons, operational errors and other sample factors.

STORAGE AND STABILITY
.The kit is 18 months shelf-life from the date of manufacture. Store the unused kits at 2-30°C. DO NOT FREEZE. Do not use beyond the expiration date.

.Do not open the sealed pouch until you are ready to perform a test, and the single-use test is suggested to be used under the required environment (temperature 2-35℃, humidity 40-90%) within 60 mins as quickly as possible.
.Sample diluent is used immediately after being opened.

WARNINGS AND PRECAUTIONS
.The kit should be sealed and protected against moisture.

.All positive specimens shall be validated by other methodologies.
.All specimens shall be treated as potential pollutant.
.DO NOT use expired reagent.
.DO NOT interchange reagents among kits with different lot no..
.DO NOT reuse test cards and any disposable accessories.
.Misoperation, excessive or little sample can lead to result deviations.

LIMITATION
.As with any assay employing mouse antibodies, the possibility exists for interference by human anti-mouse antibodies (HAMA) in the specimen. Specimens from patients who have received preparations of monoclonal antibodies for diagnosis or therapy may contain HAMA. Such specimens may cause false positive or false negative results.

.This test result is only for clinical reference, should not serve as the only basis for clinical diagnosis and treatment, the patients clinical management should be comprehensive consideration combined with its symptoms, medical history, other laboratory examination, treatment response, epidemiology and other information.
.This reagent is only used for serum and plasma tests. It may not obtain accurate result when used for other samples such as saliva and urine and etc.

PERFORMANCE CHARACTERISTICS

Linearity 20nmol/L to 320nmol/L relative deviation:-15% to +15%.
Linear correlation coefficient:(r)≥0.9900
Accuracy The recovery rate shall be within 85% – 115%.
Repeatability CV≤15%
Specificity(None of the substances at the interferent tested interfered in the assay) Interferent Interferent concentration
Hemoglobin 200μg/mL
transferrin 100μg/mL
Horseradish Peroxidase 2000μg/mL
rT3 100ng/mL
T3 500ng/mL

REFERENCES
1.Hansen JH,et al.HAMA Interference with Murine Monoclonal Antibody-Based Immunoassays[J].J of Clin Immunoassay,1993,16:294-299.

2.Levinson SS.The Nature of Heterophilic Antibodies and the Role in Immunoassay Interference[J].J of Clin Immunoassay,1992,15:108-114.

Key to symbols used:

 t11-1 In Vitro Diagnostic Medical Device
 tt-2 Manufacturer
 tt-71 Store at 2-30℃
 tt-3 Expiration Date
 tt-4 Do Not Reuse
 tt-5 CAUTION
 tt-6 Consult Instructions For Use

Xiamen Wiz Biotech CO.,LTD
Address:3-4 Floor,NO.16 Building,Bio-medical Workshop,2030 Wengjiao West Road,Haicang District,361026,Xiamen,China
Tel:+86-592-6808278
Fax:+86-592-6808279


Product detail pictures:

OEM/ODM Factory Digestion Analyzer - Diagnostic Kit for Total Thyroxine  (fluorescence immunochromatographic assay) – Baysen detail pictures


Related Product Guide:
Cardiac Biomarkers Market To Reach $13.3 Billion By 2024: Grand View Research, Inc. | Psa Test Cost
Wales ‘behind’ in technology to detect prostate cancer | Diagnostic Kit For Isoenzyme Mb Of C Reatine Kinase

We know that we only thrive if we can guarantee our combined price competiveness and quality advantageous at the same time for OEM/ODM Factory Digestion Analyzer - Diagnostic Kit for Total Thyroxine (fluorescence immunochromatographic assay) – Baysen , The product will supply to all over the world, such as: Albania, Algeria, Saudi Arabia, We solution have passed through the national skilled certification and been well received in our key industry. Our specialist engineering team will often be ready to serve you for consultation and feedback. We've been able to also provide you with no cost samples to meet your needs. Best efforts are going to be produced to supply you the very best service and solutions. For anyone who is considering our business and solutions, please speak to us by sending us emails or get in touch with us right away. As a way to know our items and enterprise. lot more, you'll be able to come to our factory to find out it. We'll constantly welcome guests from around the globe to our firm. o build enterprise. elations with us. You should really feel absolutely free to make contact with us for small business and we believe we'll share the top trading practical experience with all our merchants.
  • As an international trading company, we have numerous partners, but about your company, I just want to say, you are really good, wide range, good quality, reasonable prices, warm and thoughtful service, advanced technology and equipment and workers have professional training, feedback and product update is timely, in short, this is a very pleasant cooperation, and we look forward to the next cooperation!
    5 Stars By Moira from Oslo - 2015.09.29 17:23
    We feel easy to cooperate with this company, the supplier is very responsible, thanks.There will be more in-depth cooperation.
    5 Stars By Maureen from Poland - 2015.09.21 11:44