OEM/ODM Factory Body Analyzer Machine - Diagnostic Kit for Cardiac Troponin I ( Fluorescence Immuno Assay) – Baysen

short description:


Product Detail

Product Tags

Related Video

Feedback (2)

Our personnel are generally in the spirit of "continuous improvement and excellence", and together with the outstanding top quality merchandise, favorable price tag and fantastic after-sales solutions, we try to gain every single customer's rely on for Chlamydia Urine Test , Fsh Test Kit , Analyzer Machine , We sincerely welcome pals to negotiate enterprise and start cooperation. We hope to join hands with pals in different industries to produce a outstanding foreseeable future.
OEM/ODM Factory Body Analyzer Machine - Diagnostic Kit for Cardiac Troponin I ( Fluorescence Immuno Assay) – Baysen Detail:

FOB Brochure

3.cTnl
4 (1)
4 (2)

PRINCIPLE AND PROCEDURE OF FOB TEST

Princple:

The strip has anti-FOB coating antibody on test region, which is fastened to membrane chromatography in advance. Lable pad is coated by fluorescence labeled anti-FOB antibody in advance. When testing positive sample, the FOB in sample can be mixed with fluorescence labeled anti-FOB antibody, and form immune mixture. As the mixture is allowed to migrate along the test strip, the FOB conjugate complex is captured by anti-FOB coating antibody on the membrane and forms complex. The fluorescence intensity is positively correlated with the FOB content. The FOB in sample can be detected by fluorescence immunoassay analyzer.

Test Procedure:

1.Lay aside all reagents and samples to room temperature.
2.Open the Portable Immune Analyzer(WIZ-A101), enter the account password login according to the operation method of the instrument, and enter the detection interface.
3.Scan the dentification code to confirm the test item.
4.Take out the test card from the foil bag.
5.Insert the test card into the card slot, scan the QR code, and determine the test item.
6.Remove the cap from the sample tube and discard the first two drops diluted sample, add 3 drops (about 100uL) no bubble diluted sample verticaly and slowly into sample well of the card with provided dispette.
7.Click the “standard test” button, after 15 minutes, the instrument will automatically detect the test card, it can read the results from the display screen of the instrument, and record/print the test results.
8.Refer to the instruction of Portable Immune Analyzer(WIZ-A101).

packing

You May like


Home used SARS-CoV-2 Antigen Rapid Test(Colloidal Gold)


SARS-CoV-2 Antigen Rapid Test(Colloidal Gold)


WIZ-A101 Portable Immune Analyzer


WIZ-A101 Portable Immune Analyzer


6. 超级链接第三个产品的图片CK-MB

Diagnostic Kit for Isoenzyme MB of Creatine Kinase (Fluorescence Immunochromatographic Assay)

About Us

贝尔森主图_conew1

Xiamen Baysen Medical Tech limited is a high biological enterprise which devotes itself to filed of fast diagnostic reagent and integrates research and development, production and sales into a whole. There are many advanced research staffs and sales managers in the company, all of them are have rich working experience in china and international biopharmaceutical enterprise.

Certificate display

dxgrd


Product detail pictures:

OEM/ODM Factory Body Analyzer Machine - Diagnostic Kit for Cardiac Troponin I ( Fluorescence Immuno Assay) – Baysen detail pictures

OEM/ODM Factory Body Analyzer Machine - Diagnostic Kit for Cardiac Troponin I ( Fluorescence Immuno Assay) – Baysen detail pictures

OEM/ODM Factory Body Analyzer Machine - Diagnostic Kit for Cardiac Troponin I ( Fluorescence Immuno Assay) – Baysen detail pictures

OEM/ODM Factory Body Analyzer Machine - Diagnostic Kit for Cardiac Troponin I ( Fluorescence Immuno Assay) – Baysen detail pictures


Related Product Guide:
How the controversial PSA test for prostate cancer is making a comeback | Diagnostic Kit For Isoenzyme Mb Of C Reatine Kinase
Beyond Ben Stiller’s advice: What the experts say about PSA screening | P24 Test Strips

Our well-equipped facilities and exceptional good quality manage throughout all stages of production enables us to guarantee total shopper satisfaction for OEM/ODM Factory Body Analyzer Machine - Diagnostic Kit for Cardiac Troponin I ( Fluorescence Immuno Assay) – Baysen , The product will supply to all over the world, such as: Los Angeles, Belgium, Latvia, When It produced, it making use of the world's major method for reliable operation, a low failure price, it appropriate for Jeddah shoppers choice. Our enterprise. s situated inside the national civilized cities, the website traffic is very hassle-free, unique geographical and financial circumstances. We pursue a "people-oriented, meticulous manufacturing, brainstorm, make brilliant" company philosophy. Strict good quality management, fantastic service, affordable cost in Jeddah is our stand around the premise of competitors. If needed, welcome to make contact with us by our web page or phone consultation, we will be delighted to serve you.
  • The company leader recept us warmly, through a meticulous and thorough discussion, we signed a purchase order. Hope to cooperate smoothly
    5 Stars By Frank from Iran - 2016.06.19 13:51
    It is a very good, very rare business partners, looking forward to the next more perfect cooperation!
    5 Stars By Martha from United Arab Emirates - 2015.06.30 17:29