Our development depends on the advanced equipment, excellent talents and continuously strengthened technology forces for Faecal Calprotectin Test , Progesterone Analyzer , Diagnostic Kit For Stimulating Hormone , As a leading manufacture and exporter, we appreciate a great status inside the international markets, especially in America and Europe, because of our top high-quality and sensible charges.
OEM/ODM China Hepatitis B Surface Antigen - Diagnostic kit for Microalbuminuria (Alb) – Baysen Detail:

Diagnostic Kit for Urine microalbumin

(Fluorescence Immunochromatographic Assay)

For in vitro diagnostic use only

Please read this package insert carefully prior to use and strictly follow the instructions. Reliability of assay results cannot be guaranteed if there are any deviations from the instructions in this package insert.

INTENDED USE

Diagnostic Kit for Urine microalbumin (Fluorescence Immunochromatographic Assay) is suitable for the quantitative detection of microalbumin in human urine by fluorescence immunochromatographic assay, which is mainly used for the auxiliary diagnosis of kidney disease.All positive sample must be confirmed by other methodologies. This test is intended for healthcare professional use only.

SUMMARY

Microalbumin is a normal protein found in the blood and is extremely rare in urine when metabolized normally. If there’s a trace amount in the urine Albumin in more than 20 micron /mL, belongs to urinary microalbumin, if can be timely treatment, can completely repair the glomeruli, eliminate proteinuria, if not timely treatment, may enter the uremia phase.The increase of urinary microalbumin is mainly seen in diabetic nephropathy, hypertension and preeclampsia in pregnancy. The condition can be accurately diagnosed by the value of urinary microalbumin, combined with the incidence, symptoms and medical history. Early detection of urinary microalbumin is very important to prevent and delay the development of diabetic nephropathy.

PRINCIPLE OF THE PROCEDURE

The membrane of the test device is coated with ALB antigen on the test region and goat anti rabbit IgG antibody on the control region. Marker pad are coated by fluorescence mark anti ALB antibody and rabbit IgG in advance. When testing sample, ALB in sample combine with fluorescence marked anti ALB antibody, and form immune mixture. Under the action of the immunochromatography, the complex flow in the direction of absorbent paper, when complex passed the test region, The free fluorescent marker will be combined with ALB on the membrane.The concentration of ALB is negative correlation for fluorescence signal, and the concentration of ALB in sample can be detected by fluorescence immunoassay assay.

REAGENTS AND MATERIALS SUPPLIED

25T package components

Test card individually foil pouched with a desiccant 25T

Package insert 1

MATERIALS REQUIRED BUT NOT PROVIDED

Sample collection container,timer

SAMPLE COLLECTION AND STORAGE

  1. The samples tested can be urine.
  2. Fresh urine samples can be collected in a disposable clean container. It is recommended to test the urine samples immediately after collection. If the urine samples cannot be tested immediately, please store them at 2-8 , but it is recommended not to store them for more than 12 hours. Do not shake the container. If there is sediment at the bottom of the container, take supernatant for testing.
  3. All sample avoid freeze-thaw cycles.
  4. Thaw samples to room temperature before use.

Product detail pictures:

OEM/ODM China Hepatitis B Surface Antigen - Diagnostic kit for Microalbuminuria (Alb) – Baysen detail pictures

OEM/ODM China Hepatitis B Surface Antigen - Diagnostic kit for Microalbuminuria (Alb) – Baysen detail pictures

OEM/ODM China Hepatitis B Surface Antigen - Diagnostic kit for Microalbuminuria (Alb) – Baysen detail pictures


Related Product Guide:
Cleveland Diagnostics Study Finds Its IsoPSA Test Outperforms Standard PSA Testing | P24 Test Strips
Translocation of a gut pathobiont drives autoimmunity in mice and humans | Cpn-Igm

owing to fantastic assistance, a variety of high quality goods, aggressive rates and efficient delivery, we love a very good popularity among our customers. We are an energetic firm with wide market for OEM/ODM China Hepatitis B Surface Antigen - Diagnostic kit for Microalbuminuria (Alb) – Baysen , The product will supply to all over the world, such as: Islamabad, Albania, Dominica, During in 11 years, We have participated in more than 20 exhibitions, obtains the highest praise from each customer. Our company has been devoting that "customer first" and committed to helping customers expand their business, so that they become the Big Boss !
  • Company director has very rich management experience and strict attitude, sales staff are warm and cheerful, technical staff are professional and responsible,so we have no worry about product,a nice manufacturer.
    5 Stars By Helen from Saudi Arabia - 2015.02.08 16:45
    The company keeps to the operation concept "scientific management, high quality and efficiency primacy, customer supreme", we have always maintained business cooperation. Work with you,we feel easy!
    5 Stars By Cora from Colombia - 2016.06.25 12:48