Manufacturing Companies for Water Tank Level Gauge - Diagnostic Kit for Cardiac Troponin I ( Fluorescence Immuno Assay) – Baysen

short description:


Product Detail

Product Tags

Related Video

Feedback (2)

With our superb management, potent technical capability and strict quality command procedure, we go on to provide our shoppers with trustworthy high-quality, reasonable costs and outstanding services. We goal at becoming considered one of your most trustworthy partners and earning your pleasure for Helicobacter , Fob Rapid Test Strip , Estradiol Test Kit , Quality is factory' life , Focus on customer' demand is the source of company survival and development, We adhere to honesty and good faith working attitude, looking forward to your coming !
Manufacturing Companies for Water Tank Level Gauge - Diagnostic Kit for Cardiac Troponin I ( Fluorescence Immuno Assay) – Baysen Detail:

FOB Brochure

3.cTnl
4 (1)
4 (2)

PRINCIPLE AND PROCEDURE OF FOB TEST

Princple:

The strip has anti-FOB coating antibody on test region, which is fastened to membrane chromatography in advance. Lable pad is coated by fluorescence labeled anti-FOB antibody in advance. When testing positive sample, the FOB in sample can be mixed with fluorescence labeled anti-FOB antibody, and form immune mixture. As the mixture is allowed to migrate along the test strip, the FOB conjugate complex is captured by anti-FOB coating antibody on the membrane and forms complex. The fluorescence intensity is positively correlated with the FOB content. The FOB in sample can be detected by fluorescence immunoassay analyzer.

Test Procedure:

1.Lay aside all reagents and samples to room temperature.
2.Open the Portable Immune Analyzer(WIZ-A101), enter the account password login according to the operation method of the instrument, and enter the detection interface.
3.Scan the dentification code to confirm the test item.
4.Take out the test card from the foil bag.
5.Insert the test card into the card slot, scan the QR code, and determine the test item.
6.Remove the cap from the sample tube and discard the first two drops diluted sample, add 3 drops (about 100uL) no bubble diluted sample verticaly and slowly into sample well of the card with provided dispette.
7.Click the “standard test” button, after 15 minutes, the instrument will automatically detect the test card, it can read the results from the display screen of the instrument, and record/print the test results.
8.Refer to the instruction of Portable Immune Analyzer(WIZ-A101).

packing

You May like


Home used SARS-CoV-2 Antigen Rapid Test(Colloidal Gold)


SARS-CoV-2 Antigen Rapid Test(Colloidal Gold)


WIZ-A101 Portable Immune Analyzer


WIZ-A101 Portable Immune Analyzer


6. 超级链接第三个产品的图片CK-MB

Diagnostic Kit for Isoenzyme MB of Creatine Kinase (Fluorescence Immunochromatographic Assay)

About Us

贝尔森主图_conew1

Xiamen Baysen Medical Tech limited is a high biological enterprise which devotes itself to filed of fast diagnostic reagent and integrates research and development, production and sales into a whole. There are many advanced research staffs and sales managers in the company, all of them are have rich working experience in china and international biopharmaceutical enterprise.

Certificate display

dxgrd


Product detail pictures:

Manufacturing Companies for Water Tank Level Gauge - Diagnostic Kit for Cardiac Troponin I ( Fluorescence Immuno Assay) – Baysen detail pictures

Manufacturing Companies for Water Tank Level Gauge - Diagnostic Kit for Cardiac Troponin I ( Fluorescence Immuno Assay) – Baysen detail pictures

Manufacturing Companies for Water Tank Level Gauge - Diagnostic Kit for Cardiac Troponin I ( Fluorescence Immuno Assay) – Baysen detail pictures

Manufacturing Companies for Water Tank Level Gauge - Diagnostic Kit for Cardiac Troponin I ( Fluorescence Immuno Assay) – Baysen detail pictures


Related Product Guide:
Pharmacological Postconditioning with Lactic Acid and Hydrogen Rich Saline Alleviates Myocardial Reperfusion Injury in Rats | P24 Test Strips
A New $500 Blood Test Could Detect Cancer Before Symptoms Develop | Diagnostic Kit For Isoenzyme Mb Of C Reatine Kinase

Our firm since its inception, normally regards item top quality as company life, constantly make improvements to generation technology, improve product excellent and repeatedly strengthen organization total good quality management, in strict accordance with the national standard ISO 9001:2000 for Manufacturing Companies for Water Tank Level Gauge - Diagnostic Kit for Cardiac Troponin I ( Fluorescence Immuno Assay) – Baysen , The product will supply to all over the world, such as: Toronto, Greece, St. Petersburg, Being guided by customer demands, aiming at improving the efficiency and quality of customer service, we constantly improve products and provide more comprehensive services. We sincerely welcome friends to negotiate business and start cooperation with us. We hope to join hands with friends in different industries to create a brilliant future.
  • After the signing of the contract, we received satisfactory goods in a short term, this is a commendable manufacturer.
    5 Stars By Aaron from azerbaijan - 2015.10.01 14:14
    This is a very professional wholesaler, we always come to their company for procurement, good quality and cheap.
    5 Stars By Nancy from Slovenia - 2015.10.01 14:14