Diagnostic ornamentum pro Antigen ad Helicobacter Pylori (Fluorescence Immunochromatographic Asay)

Short description:


  • Temptatione Tempus:10-15 minutes
  • Valet Time:XXIV mensis
  • Accuratio:Plus quam XCIX%
  • Specification:1/25 Test / Box
  • Storage temperatus:II ℃ -30 ℃
  • Product Detail

    Product Tags

    Diagnostic ornamentum pro Antigen ad Helicobacter Pylori(Fluorizing Immunochromatographic Asay)
    Nam in vitro diagnostic usu modo

    Please legit hoc sarcina insert diligenter prior ad uti et stricte sequi instructiones. Reliability Assay praecessi non potest praestati si sunt aliqua deviationes ex instructiones in hoc sarcina inserta.

    Intendebat usum
    Helelobacter Pylori Helicobacter est Helicobacter (Fluorcia Immunochromatographic) est idoneam ad quantitatis humana stercore HP Antigen per Fluorcence Immunochromatographic Assay, quae habet magna accessorium Diagnostic pretii pro CARDIACUS. Omnes positivum sample debet confirmari ab aliis methodologies. Hoc test est in animo pro curis professional usum tantum.

    Summary
    CARDIACUS helicobacter pylori infectio est propinqua cum inveterata GASTRITIS, CARDIACUS ulceris, CARDIACUS adenocarcinoma, CARDIACUS mucosa consociata Lymphoma, HP IRCUS infectio de XC% in GASTRIRIC. Mundus Salus Organization habet identified h. Pyloristis sicut primum genus cancer-causat elementum et scilicet periculum factor in CARDIRIC cancer.h.plori deprehensio est magni valorem in diagnosis H. Pylori Inffection.The Test secundum Fluoren Immunochromatographic Assay Analysis technics, quae potest dare effectus in XV minutes.

    Principle procedendi

    Et habena habet anti-HP coating antibody in test regionem, quae est ad membranam chromatography in antecessum. Lables codex est iactaret fluorescen intitulatum anti-HP antibody in antecessum. Cum probatio positivum sample, in HP in sample potest misceri cum fluorescence intitulatum anti-HP, et forma immune mixtisque. Ut mixtisque licet migrare per test habena, in HP Conjugate complexu captum per anti-HP coating antibody in membrana et formas complexu. Fluorence intensionem est positive connectuntur cum HP contentus. HP in sample potest deprehendi a fluorescence immunoassay analyser.

    Reagentia et materiae suppleverunt

    25T sarcina components:
    Test card singulos ffoyle pouched cum a desiccant 25t
    Sample diluents 25t
    Package Insert I

    Materials requiritur sed non provisum
    Sample Collection Container, Timer

    Sample Collection et Storage
    1.Use a PROMPTU mundus continens colligere nova stercore sample et probata statim. Si non probata statim, placere repono 2-8 ° C ad III diebus et infra -15 ° C VI mensibus.

    2.Take ex sampling lignum, inserta in stercore sample, repetere actio III tempora, ut diversis partibus in sample sampling sampling et excutite bene, aut per sample lignum et excutite bene, aut per sampling lignum et excutite bene, aut per sampling lignum et excutite bene, aut usura sample lignum et excutite bene, aut per sample lignum et excutite bene, aut per sample lignum et excutite bene, aut per sample lignum et excutite bene, aut usura sample lignum et excutite bene, aut usura sample lignum et excutite bene, aut per sampling lignum et excutite bene, aut per sampling lignum et excutite bene, aut per sample lignum et excutite bene, aut per sample lecta De 50 sames sames et in stercore sample fistulam continens sample Globuli et screw arcte.
    3.Use Disposable Pipette sampling accipere in stercore sample ex fluxus patientes estote, deinde add III guttae (de 100μl) ad Fecal sampling tubo et excutite bene.

    Praecipua:
    1.ovoid Frigidus-CALEFICIUM CYCLII.

    2.Thaw exempla ad locus temperatus ante usum.

    Procedure
    Placere legit instrumentum operationem manual et sarcina inserta ante tentat.

    1.Lay intrahunt omnes reagentia et exempla ad locus temperatus.
    2.Open in portable immune analyzer (wiz-a101), Intra rationem password login secundum operationem modum instrumenti, et intrare deprehendatur interface.
    3.Scan dentification codice confirmare test item.
    4.Take de test card de ffoyle peram.
    5.Insert in test card in card socors, scan in QR code, determinare test item.
    6.Remove cap a sample fistulam et abiicias primum duo guttae dilutius sample, addere III guttae (de 100UL) non bulla dilutius sample vertically et tardius in sample bene de card cum dampeto.
    7.Click in "Latin test" puga pyga, post XV minuta, instrumentum et automatice deprehendere in test card, quod potest lego eventus ex ostentationem screen of instrumenta et record / print in test results.
    8.Refer ad disciplinam Portable immune analyzer (wiz-a101).
    probo

    Expectata values
    HP-AG <X

    Commendatur quod quisque laboratorium statuam suam normalem range representing sua patientes estote population.

    Test eventus et interpretatione
    1.The HP-AG in sample plus quam X, et ut praeesset ex mutatione de physiologica statu. Eventus quidem abnormes et sit diagnosed cum orci docebo.

    2.the results of hunc modum sunt tantum applicabiles ad reference Ranges statutum in modum, et non est recta comparability cum aliis modi.
    3.Othe factors potest etiam causa errores deprehendendi results, comprehendo technica rationes, operational errores et alia sample factors.

    Repono et stabilitatem
    1.The ornamentum est XVIII menses PLUTEUM-vita a date de fabricantibus. Store ad insolita rhoncus ad 2-30 ° c. Nolite rigabant. Noli ultra expirata.

    2.Do non aperire signatum massa usque ad vos es parati ad praestare a test et una-usu test suggesserant utendum sub requiritur environment (temperatus 2-35 ℃, humiditas 40-90%) in LX min ut cito quam maxime.
    3.Sample diluent adhibetur statim postquam aperuit.

    Monitus et cautiones
    .The ornamentum sit signari et protected contra humorem.

    .All positivum specimina erit convalescere ab aliis methodologies.
    .All specimens et tractata est potentiale pollutant.
    .Do non utor exspiravit Reagent.
    .Do non intercedit Reagents inter Kits cum diversis sorte non ..
    .Do non reuse test cards et nihil PROMPTIOCCULA.
    .Misoperation, nimia aut parum specimen potest ad eventum deviationibus.

    LImitatio
    .As cum aliquo assau usus mus elibodarum, facultatem existit pro intercessiones ab humana anti-mus elencodies (Hama) in specimine. Specimens aegris qui accepit apparatu of Monoclonal antibodies ad diagnosi vel illic ut quae Hama. Tales specimina potest causare falsum positivum vel falsum negative praecessi.

    .This test result is only for clinical reference, should not serve as the only basis for clinical diagnosis and treatment, the patients clinical management should be comprehensive consideration combined with its symptoms, medical history, other laboratory examination, treatment response, epidemiology and other information .
    .This Reagent est solum usus est FECAL probat. Non potest obtinere accurate consequuntur, cum usus ad alia exempla ut saliva et urina etc.

    Perficientur characteres

    Lineamentum 10-1000 Relativum deviation: -15% ad + XV%.
    Linear Correlation coefficiente (R) ≥0,9900
    Accuratio Et recuperatio rate erit in LXXXV% - CXV%.
    Repeatability CV≤15%

    RE

    1.Shao, JL & f.wu.recent progressus in detectionem modi de helicobacter Pylori [J] .Journal et Hepatology, 2012,21 (VIII) 691-694
    2.hansen JH, et al.hama intercessiones cum murine monoclonal antibody-fundatur immunoassays [J] .j de Clin Immunoassay, 1993,16: 294-299.
    3.Levinson ss.The natura heterophilic antibodies et munus in immunoassay intercessiones [J] .j de Clin Immunoassay, 1992,15, 108-114.

    Key ad symbola usus:

     T11-1 In Vitro Diagnostic Medical fabrica
     TT-II Manufacturer
     TT-LXXI Store ad 2-30 ℃
     TT-III Expiration Date
     TT-IV Non reuse
     T-V Cautio
     TT-VI Consule instructiones ad usum

    Xiamen Vivamus Biotech Co., Ltd
    Oratio: 3-4 area, no.16 aedificationem, bio-medical officia, MMXXXX Wengjiao Occidentem Road, Haicang regio, (XXXVI) CXXVI, Xiamen, Sina
    Tel: + 86-592-6808278
    Fax: + 86-592-6808279