High reputation Diagnostic Hiv 1/2 Rapid Test Kit - Diagnostic Kit(Colloidal Gold)for IgM Antibodv to Chlamydia Pneumoniae – Baysen

short description:


Product Detail

Product Tags

Related Video

Feedback (2)

We will devote ourselves to providing our esteemed customers with the most enthusiastically thoughtful services for Afp Medical Kit , Nt Probnp Test Kit , Cea Diagnostick Kit , Our group members are goal to provides merchandise with significant performance cost ratio to our consumers, as well as target for all of us is usually to satisfy our consumers from all around the environment.
High reputation Diagnostic Hiv 1/2 Rapid Test Kit - Diagnostic Kit(Colloidal Gold)for IgM Antibodv to Chlamydia Pneumoniae – Baysen Detail:

Diagnostic KitColloidal Goldfor IgM Antibodv to Chlamydia Pneumoniae
For in vitro diagnostic use only

Please read this package insert carefully prior to use and strictly follow the instructions. Reliability of assay results cannot be guaranteed if there are any deviations from the instructions in this package insert.

INTENDED USE
Diagnostic Kit(Colloidal Gold)for IgM Antibodv to Chlamydia Pneumoniae is a colloidal gold immunochromatographic assay for the qualitative determination of IgM Antibody to Chlamydia Pneumoniae (Cpn-IgM) in human whole blood,serum or plasma, it acts as chlamydia pneumonia infection auxiliary diagnosis reagent in clinical diagnosis. Meanwhile it is a screening reagent. All positive sample must be confirmed by other methodologies.This test is intended for healthcare professional use only. 

PACKAGE SIZE
1 kit /box, 10 kits /box, 25 kits,/box, 50 kits /box

SUMMARY
Chlamydia pneumoniae is an important pathogen of respiratory infection, it can cause upper respiratory tract infection,such as sinusitis, otitis and pharyngitis, and lower respiratory tract infection, such as bronchitis and pneumonia.The Diagnostic Kit is a simple, visual qualitative test that detects Cpn-Igm in human whole blood, serum or plasma. The Diagnostic Kit is based on immunochromatography and can give a result within 15 minutes.

Applicable instrument
Except visual inspection, the kit can be matched with Continuous immune analyzer WIZ-A202 of Xiamen Wiz Biotech Co., Ltd 

ASSAY PROCEDURE
The WIZ-A202 test procedure see the instruction of Continuous immune analyzer. Visual test procedure is as follows

1.Take out the test card from the foil bag, put it on the level table and mark it;
2.Add 10μl serum or plasma sample or 20ul whole blood sample to sample well of the card with provided dispette, then add 100μl (about 2-3 drop) sample diluent; start timing;
3.Wait for a minimum 10-15 minutes and read the result, the result is invalid after 15 minutes.


Product detail pictures:

High reputation Diagnostic Hiv 1/2 Rapid Test Kit - Diagnostic Kit(Colloidal Gold)for IgM Antibodv to Chlamydia Pneumoniae – Baysen detail pictures


Related Product Guide:
Oulton BSB: Valentine backs Haslam despite engine woes | Cpn-Igm
Tricare for Life Users Surprised by Drug Cost Increase | Cpn-Igm

We always work as a tangible team to ensure that we can provide you with the best quality and the best price for High reputation Diagnostic Hiv 1/2 Rapid Test Kit - Diagnostic Kit(Colloidal Gold)for IgM Antibodv to Chlamydia Pneumoniae – Baysen , The product will supply to all over the world, such as: Honduras, Qatar, Madagascar, All styles appear on our website are for customizing. We meet up to personal requirements with all products of your very own styles. Our concept is to help presenting the confidence of each buyers with the offering of our most sincere service, and the right product.
  • This enterprise in the industry is strong and competitive, advancing with the times and develop sustainable, we are very pleased to have a opportunity to cooperate!
    5 Stars By Doris from Angola - 2015.06.03 10:17
    The factory workers have rich industry knowledge and operational experience, we learned a lot in working with them,we are extremely grateful that we can encount a good company has excellent wokers.
    5 Stars By Martha from Jeddah - 2016.04.08 14:55