High Quality for High-precision Level Transmitter - Diagnostic Kit(LATEX)for Rotavirus Group A – Baysen
High Quality for High-precision Level Transmitter - Diagnostic Kit(LATEX)for Rotavirus Group A – Baysen Detail:
Diagnostic Kit(LATEX)for Rotavirus Group A
For in vitro diagnostic use only
Please read this package insert carefully prior to use and strictly follow the instructions. Reliability of assay results cannot be guaranteed if there are any deviations from the instructions in this package insert.
INTENDED USE
Diagnostic Kit(LATEX)for Rotavirus Group A is suitable for qualitative detection of Rotavirus Group A antigen in human fecal samples. This test is intended for healthcare professional use only. Meanwhile, this test is used for the clinical diagnosis of infantile diarrhea in patients with Rotavirus Group A infection.
PACKAGE SIZE
1 kit /box, 10 kits /box, 25 kits,/box, 50 kits /box.
SUMMARY
Rotavirus is classified as a rotavirus genus of the exenteral virus, which has a spherical shape with a diameter of about 70nm. Rotavirus contains 11 segments of double-stranded RNA. The rotavirus can be seven groups (a-g) based on antigenic differences and gene characteristics. Human infections of group A, group B and C group rotavirus have been reported. Rotavirus Group A is the important cause of severe gastroenteritis in children worldwide[1-2].
ASSAY PROCEDURE
1.Take out the sampling stick, inserted into the faeces sample, then put the sampling stick back, screw tight and shake well, repeat the action 3 times. Or using the sampling stick picked about 50mg faeces sample, and put in a faeces sample tube containing sample dilution, and screw tightly.
2.Use disposable pipette sampling take the thinner faeces sample from the diarrhea patient, then add 3 drops (about 100uL) to the fecal sampling tube and shake well, put aside.
3.Take out the test card from the foil bag, put it on the level table and mark it.
4.Remove the cap from the sample tube and discard the first two drops diluted sample, add 3 drops (about 100uL) no bubble diluted sample verticaly and slowly into sample well of the card with provided dispette, start timing.
5.The result should be read within 10-15 minutes, and it is invalid after 15 minutes.
Product detail pictures:
Related Product Guide:
Benefits of PSA test to screen for prostate cancer are roughly equal to its harms, expert panel says | Cpn-Igm
Why I Won’t Get a PSA Test for Prostate Cancer | Cpn-Igm
We provide fantastic energy in top quality and advancement,merchandising,gross sales and marketing and operation for High Quality for High-precision Level Transmitter - Diagnostic Kit(LATEX)for Rotavirus Group A – Baysen , The product will supply to all over the world, such as: Mauritius, Belgium, Barcelona, We have been seeking the chances to meet all the friends from both at home and abroad for the win-win cooperation. We sincerely hope to have long-term cooperation with all of you on the bases of mutual benefit and common development.
By Helen from panama - 2016.09.09 10:18
The company's products can meet our diverse needs, and the price is cheap, the most important is that the quality is also very nice.
By Gwendolyn from Iraq - 2016.11.20 15:58