High Quality for Antibody Igg(mp) Elisa Test Kits - fer rapid test kit ivd reagent ferrtin kit – Baysen

short description:


Product Detail

Product Tags

Related Video

Feedback (2)

We're going to commit ourselves to giving our esteemed buyers using the most enthusiastically considerate solutions for Chemiluminescence Immunoassay , Diagnostic Kit For Estradiol , Renal Function Test Kit , We warmly welcome customers from all over the world for any kind of cooperation with us to build a mutual benefit future. We are devoting ourselves wholeheartedly to offer customers the best service.
High Quality for Antibody Igg(mp) Elisa Test Kits - fer rapid test kit ivd reagent ferrtin kit – Baysen Detail:

Products Parameters

3.FER

PRINCIPLE AND PROCEDURE OF FOB TEST

PRINCIPLE

The membrane of the test device is coated with anti FER antibody on the test region and goat anti rabbit IgG antibody on the control region. Lable pad are coated by fluorescence labeled anti FER antibody and rabbit IgG in advance. When testing positive sample, the FER antigen in sample combine with fluorescence labeled anti FER antibody, and form immune mixture. Under the action of the immunochromatography, the complex flow in the direction of absorbent paper, when complex passed the test region, it combined with anti FER coating antibody, forms new complex.FER level is positively correlated with fluorescence signal, and the concentration of FER in sample can be detected by fluorescence immunoassay assay.

Test Procedure

Please read the instrument operation manual and package insert before testing.

1. Lay aside all reagents and samples to room temperature.
2. Open the Portable Immune Analyzer(WIZ-A101), enter the account password login according to the operation method of the instrument, and enter the detection interface.
3. Scan the dentification code to confirm the test item.
4. Take out the test card from the foil bag.
5. Insert the test card into the card slot, scan the QR code, and determine the test item.
6. Add 40μL serum or plasma sample into sample diluent, and mix well..
7. Add 80μL sample solution to sample well of the card.
8. Click the “standard test” button, after 15 minutes, the instrument will automatically detect the test card, it can read the results from the display screen of the instrument, and record/print the test results.
9. Refer to the instruction of Portable Immune Analyzer(WIZ-A101).

packing

You May like


Home used SARS-CoV-2 Antigen Rapid Test(Colloidal Gold)


SARS-CoV-2 Antigen Rapid Test(Colloidal Gold)


WIZ-A101 Portable Immune Analyzer


WIZ-A101 Portable Immune Analyzer


6.超级链接第三产品图片VD


Diagnostic Kit for 25-hydroxy Vitamin D (Fluorescence Immunochromatographic Assay)

About Us

贝尔森主图_conew1

Xiamen Baysen Medical Tech limited is a high biological enterprise which devotes itself to filed of fast diagnostic reagent and integrates research and development, production and sales into a whole. There are many advanced research staffs and sales managers in the company, all of them are have rich working experience in china and international biopharmaceutical enterprise.

Certificate display

dxgrd


Product detail pictures:

High Quality for Antibody Igg(mp) Elisa Test Kits - fer rapid test kit  ivd reagent ferrtin kit – Baysen detail pictures

High Quality for Antibody Igg(mp) Elisa Test Kits - fer rapid test kit  ivd reagent ferrtin kit – Baysen detail pictures

High Quality for Antibody Igg(mp) Elisa Test Kits - fer rapid test kit  ivd reagent ferrtin kit – Baysen detail pictures

High Quality for Antibody Igg(mp) Elisa Test Kits - fer rapid test kit  ivd reagent ferrtin kit – Baysen detail pictures

High Quality for Antibody Igg(mp) Elisa Test Kits - fer rapid test kit  ivd reagent ferrtin kit – Baysen detail pictures

High Quality for Antibody Igg(mp) Elisa Test Kits - fer rapid test kit  ivd reagent ferrtin kit – Baysen detail pictures

High Quality for Antibody Igg(mp) Elisa Test Kits - fer rapid test kit  ivd reagent ferrtin kit – Baysen detail pictures


Related Product Guide:
10 health checks you can get on Medicare in Australia | Calprotectin Elisa Kit
Why I Won’t Get a PSA Test for Prostate Cancer | Calprotectin Elisa Kit

Our crew through skilled training. Skilled skilled knowledge, strong sense of company, to meet the company wants of customers for High Quality for Antibody Igg(mp) Elisa Test Kits - fer rapid test kit ivd reagent ferrtin kit – Baysen , The product will supply to all over the world, such as: The Swiss, Puerto Rico, Qatar, In order to make more people know our products and to enlarge our market, we have devoted a lot of attention to technical innovations and improvement, as well as replacement of equipment. Last but not the least, we also pay more attention to training our managerial personnel, technicians and workers in planned way.
  • The supplier cooperation attitude is very good, encountered various problems, always willing to cooperate with us, to us as the real God.
    5 Stars By Ruth from Bangkok - 2015.08.12 12:27
    Reasonable price, good attitude of consultation, finally we achieve a win-win situation,a happy cooperation!
    5 Stars By Ivy from Malaysia - 2016.12.31 14:53
    Write your message here and send it to us