Factory Free sample Portable Blood Pressure Machine - Diagnostic Kit(Colloidal Gold)for Calprotectin – Baysen

short description:


Product Detail

Product Tags

Related Video

Feedback (2)

Our aim would be to fulfill our shoppers by offering golden company, very good value and good quality for Crp Rapid Test Strips , Diagnostic Kit For Procalcitonin , Fsh Test Kit , Accurate process devices, Advanced Injection Molding Equipment, Equipment assembly line, labs and software advancement are our distinguishing feature.
Factory Free sample Portable Blood Pressure Machine - Diagnostic Kit(Colloidal Gold)for Calprotectin – Baysen Detail:

Diagnostic KitColloidal Goldfor Calprotectin
For in vitro diagnostic use only

Please read this package insert carefully prior to use and strictly follow the instructions. Reliability of assay results cannot be guaranteed if there are any deviations from the instructions in this package insert.

INTENDED USE
Diagnostic Kit for Calprotectin(cal) is is a colloidal gold immunochromatographic assay for the semiquantitative determination of cal from human faeces, which has important accessory diagnostic value for inflammatory bowel disease. This test is a screening reagent. All positive sample must be confirmed by other methodologies. This test is intended for healthcare professional use only. Meanwhile, this test is used for IVD, extra instruments are not needed.

SUMMARY
Cal is a heterodimer, which is composed of MRP 8 and MRP 14. It exists in neutrophils cytoplasm and expressed on mononuclear cell membranes. Cal is acute phase proteins, it has a well stable phase about one week in human faeces, it is determined to be a inflammatory bowel disease marker. The kit is a simple, visual semiqualitative test that detects cal in human faeces, it has high detection sensitivity and strong specificity. The test based on high specificit double antibodies sandwich reaction principle and gold immunochromatographic assay analysis technics, it can give a result within 15 minutes.

PRINCIPLE OF THE PROCEDURE
The strip has anti cal coating McAb on test region and goat anti-rabbit IgG antibody on control region, which is fastened to membrane chromatography in advance. Lable pad is coated by colloidal gold labeled anti cal McAb and colloidal gold labeled rabbit IgG antibody in advance. When testing positive sample, the cal in sample comined with colloidal gold labeled anti cal McAb, and form immune complex, as it is allowed to migrate along the test strip, the cal conjugate complex is captured by anti cal coating McAb on the membrane and form “anti cal coating McAb-cal-colloidal gold labeled anti cal McAb” complex, a colored test band appeared on test region. The color intensity is positively correlated with the cal content. A negative sample does not produce a test band due to the absence of colloidal gold conjugate cal complex. No matter cal is present in sample or not, there is a red stripe appear on reference region and quality control region, which is regarded as quality internal enterprise standards.

REAGENTS AND MATERIALS SUPPLIED
25T package components

.Test card individually foil pouched with a desiccant
.Sample diluents: the ingredients is 20mM pH7.4PBS
.Dispette
.Package insert

MATERIALS REQUIRED BUT NOT PROVIDED

Sample collection container, timer

SAMPLE COLLECTION AND STORAGE
Use a disposable clean container to collect fresh faeces sample, and tested immediately. If can not be tested immediately, please stored at 2-8°C for 12hours or bellow -15°C for 4 months.

ASSAY PROCEDURE
1.Take out the sampling stick, inserted into the faeces   sample, then put the sampling stick back, screw tight and shake well, repeat the action 3 times. Or using the sampling stickpicked about 50mg faeces sample, and put in a faeces sample tube containing sample dilution, and screw tightly.

2.Use disposable pipette sampling take the thinner faeces sample from the diarrhea patient, then add 3 drops (about 100uL) to the fecal sampling tube and shake well, put aside.
3.Take out the test card from the foil bag, put it on the level table and mark it.
4.Remove the cap from the sample tube and discard the first two drops diluted sample, add 3 drops (about 100uL) no bubble diluted sample verticaly and slowly into sample well of the card with provided dispette, start timing.
5.The result should be read within 10-15 minutes, and it is invalid after 15 minutes.
d1

TEST RESULTS AND INTERPRETATION

  Test results Interpretation
Red reference band and red control bandappear on R region and C region, no redtest band on T region. It  means  the  content  of  human  faecescalprotectin  is  under15μg/g,  which  is  anormal level.
Red reference band and red control bandappear on R region and C region, and thecolor of red reference band is darker thanred test band. The content of human faeces calprotectin isbetween 15μg/g and 60μg/g. That may bein the normal level, or there may be a risk ofIrritable Bowel Syndrome.
Red reference band and red control bandappear on R region and C region, and thecolor of red reference band is same withred test band. The content of human faeces calprotectin is60μg/g,  and  there  is  existential  risk  ofinflammatory bowel disease.
Red reference band and red control bandappear on R region and C region, and thecolor of red test band is darker than redreference band. It  indicates  the  content  of  human  faecescalprotectin is more than 60μg/g, and thereis  existential  risk  of  inflammatory  boweldisease.
If red reference band and red control bandis not seen or just seen only one,the test isconsidered invalid. Repeat the test using a new test card.

y
STORAGE AND STABILITY
The kit is 24 months shelf-life from the date of manufacture. Store the unused kits at 2-30°C. Do not open the sealed pouch until you are ready to perform a test.

WARNINGS AND PRECAUTIONS
1.The kit should be sealed and protected against moisture1.

2.Do not use sample which is placed too long or repeated freezing and thawing to test
3.Fecal samples is excessive or thickness can make the diluted samples foul test card, please centrifuge the diluted sample and take the supernatant for testing.
4.Misoperation, excessive or little sample can lead to result deviations.

LIMITATION
1.This test result is only for clinical reference, should not serve as the only basis for clinical diagnosis and treatment,the patients clinical management should be comprehensive consideration combined with its symptoms, medical history,other laboratory examination, treatment response,epidemiology and other information2 .

2.This reagent is only used for fecal tests. It may not obtain accurate result when used for other samples such as saliva and urine and etc.

REFERENCES
[1] The national clinical test procedures(the third edition,2006).The ministry health department.

[2] Measures for the administration of in vitro diagnostic reagents registration. China Food and Drug Administration ,No. 5 order, 2014-07-30.
Key to symbols used:

 t11-1 In Vitro Diagnostic Medical Device
 tt-2 Manufacturer
 tt-71 Store at 2-30℃
 tt-3 Expiration Date
 tt-4 Do Not Reuse
 tt-5 CAUTION
 tt-6 Consult Instructions For Use

Xiamen Wiz Biotech CO.,LTD
Address:3-4 Floor,NO.16 Building,Bio-medical Workshop,2030 Wengjiao West Road,Haicang District,361026,Xiamen,China
Tel:+86-592-6808278
Fax:+86-592-6808279


Product detail pictures:

Factory Free sample Portable Blood Pressure Machine - Diagnostic Kit(Colloidal Gold)for Calprotectin – Baysen detail pictures

Factory Free sample Portable Blood Pressure Machine - Diagnostic Kit(Colloidal Gold)for Calprotectin – Baysen detail pictures

Factory Free sample Portable Blood Pressure Machine - Diagnostic Kit(Colloidal Gold)for Calprotectin – Baysen detail pictures


Related Product Guide:
A small molecule compound IMB-LA inhibits HIV-1 infection by preventing viral Vpu from antagonizing the host restriction factor BST-2 | Cpn-Igm
Scientists have yet to find the Holy Grail of cancer tests | Diagnostic Kit For Isoenzyme Mb Of C Reatine Kinase

Our mission is to become an innovative supplier of high-tech digital and communication devices by providing value added design, world-class manufacturing, and service capabilities for Factory Free sample Portable Blood Pressure Machine - Diagnostic Kit(Colloidal Gold)for Calprotectin – Baysen , The product will supply to all over the world, such as: Jamaica, Uzbekistan, Estonia, With the growing of the company, now our products sold and served at more than 15 countries around the world,such as Europe,North America,Middle-east,South America,Southern Asia and so on. As we bear in our mind that innovation is essential to our growth, new product development is constantly.Besides, Our flexible and efficient operation strategies,High quality products and competitive prices are exactly what our customers are looking for. Also a considerable service brings us good credit reputation.
  • Goods just received, we are very satisfied, a very good supplier, hope to make persistent efforts to do better.
    5 Stars By Matthew from Seattle - 2015.06.30 17:29
    We are really happy to find such a manufacturer that ensuring product quality at the same time the price is very cheap.
    5 Stars By Elva from St. Petersburg - 2016.09.09 10:18