China Gold Supplier for Quantum Bio Resonance Analyzer - Diagnostic Kit(Colloidal Gold)for IgM Antibodv to Chlamydia Pneumoniae – Baysen
China Gold Supplier for Quantum Bio Resonance Analyzer - Diagnostic Kit(Colloidal Gold)for IgM Antibodv to Chlamydia Pneumoniae – Baysen Detail:
Diagnostic Kit(Colloidal Gold)for IgM Antibodv to Chlamydia Pneumoniae
For in vitro diagnostic use only
Please read this package insert carefully prior to use and strictly follow the instructions. Reliability of assay results cannot be guaranteed if there are any deviations from the instructions in this package insert.
INTENDED USE
Diagnostic Kit(Colloidal Gold)for IgM Antibodv to Chlamydia Pneumoniae is a colloidal gold immunochromatographic assay for the qualitative determination of IgM Antibody to Chlamydia Pneumoniae (Cpn-IgM) in human whole blood,serum or plasma, it acts as chlamydia pneumonia infection auxiliary diagnosis reagent in clinical diagnosis. Meanwhile it is a screening reagent. All positive sample must be confirmed by other methodologies.This test is intended for healthcare professional use only.
PACKAGE SIZE
1 kit /box, 10 kits /box, 25 kits,/box, 50 kits /box
SUMMARY
Chlamydia pneumoniae is an important pathogen of respiratory infection, it can cause upper respiratory tract infection,such as sinusitis, otitis and pharyngitis, and lower respiratory tract infection, such as bronchitis and pneumonia.The Diagnostic Kit is a simple, visual qualitative test that detects Cpn-Igm in human whole blood, serum or plasma. The Diagnostic Kit is based on immunochromatography and can give a result within 15 minutes.
Applicable instrument
Except visual inspection, the kit can be matched with Continuous immune analyzer WIZ-A202 of Xiamen Wiz Biotech Co., Ltd
ASSAY PROCEDURE
The WIZ-A202 test procedure see the instruction of Continuous immune analyzer. Visual test procedure is as follows
1.Take out the test card from the foil bag, put it on the level table and mark it;
2.Add 10μl serum or plasma sample or 20ul whole blood sample to sample well of the card with provided dispette, then add 100μl (about 2-3 drop) sample diluent; start timing;
3.Wait for a minimum 10-15 minutes and read the result, the result is invalid after 15 minutes.
Product detail pictures:
Related Product Guide:
Should PSA test be free for all men in B.C.? | Psa Test Cost
Een kudtkoekiewall. Omdat dat moet, van de kudtkoekiewet. | Diagnostic Kit For Isoenzyme Mb Of C Reatine Kinase
It adheres for the tenet "Honest, industrious, enterprising, innovative" to develop new products and solutions continuously. It regards shoppers, success as its individual success. Let us produce prosperous future hand in hand for China Gold Supplier for Quantum Bio Resonance Analyzer - Diagnostic Kit(Colloidal Gold)for IgM Antibodv to Chlamydia Pneumoniae – Baysen , The product will supply to all over the world, such as: Boston, Mexico, Palestine, Custom orders are acceptable with different quality grade and customer's especial design. We are looking forward to establish the good and successful cooperation in business with long terms from the customers of all over the world.
By Jodie from Riyadh - 2016.11.12 12:31
The goods we received and the sample sales staff display to us have the same quality, it is really a creditable manufacturer.
By Lydia from Iraq - 2015.08.12 12:27