China Factory for Dengue Iggigm Rapid Test Strip - Diagnostic Kit for Procalcitonin – Baysen
China Factory for Dengue Iggigm Rapid Test Strip - Diagnostic Kit for Procalcitonin – Baysen Detail:
Diagnostic Kit for Procalcitonin
Methodology:Fluorescence Immunochromatographic Assay
Production information
Model Number | PCT | Packing | 25 Tests/ kit, 30kits/CTN |
Name |
Diagnostic Kit for Procalcitonin |
Instrument classification | Class II |
Features | High sensitivity, Easy opeation | Certificate | CE/ ISO13485 |
Accuracy | > 99% | Shelf life | Two Years |
Methodology | Fluorescence Immunochromatographic Assay | OEM/ODM service | Avaliable |
INTENDED USE
This kit is applicable to the in vitro quantitative detection on the content of procalcitonin (PCT) in human
serum/plasma/whole blood samples and is mainly used for implementing auxiliary diagnosis of clinical systemic
bacterial infection and sepsis. This kit only provides the test result of Procalcitonin, and the obtained result shall
be analyzed in combination with other clinical information.
Test procedure
1 | Before using the reagent,read the package insert carefully and familiarize yourself with the operating procedures. |
2 | Select standard test mode of WIZ-A101 portable immune analyzer |
3 | Open the aluminum foil bag package of reagent and take out the test device. |
4 | Horizontally insert the test device into the slot of immune analyzer. |
5 | On home page of operation interface of immune analyzer, click “Standard” to enter test interface. |
6 | Click “QC Scan” to scan the QR code on inner side of the kit; input kit related parameters into instrument and select sample type. Note: Each batch number of the kit shall be scanned for one time. If the batch number has been scanned, then skip this step. |
7 | Check the consistency of “Product Name”, “Batch Number” etc. on test interface with information on the kit label. |
8 | Take out sample diluent upon consistent information, add 80μL serum/plasma/whole blood sample, and thoroughly mix them; |
9 | Add 80µL aforesaid thoroughly mixed solution into well of test device; |
10 | After complete sample addition, click “Timing” and remaining test time will be automatically displayed on the interface. |
11 | Immune analyzer will automatically complete test and analysis when test time is reached. |
12 | After test by immune analyzer is completed, test result will be displayed on test interface or can be viewedthrough “History” on home page of operation interface. |
Note: each sample shall be pipetted by clean disposable pipette to avoid cross contamination.
Product detail pictures:
Related Product Guide:
MDxHealth (R): SelectMDx Cost-effective in Four European Countries Brussels Stock Exchange:MDXH | Calprotectin Elisa Kit
TXNIP/TRX/NF-κB and MAPK/NF-κB pathways involved in the cardiotoxicity induced by Venenum Bufonis in rats | Cpn-Igm
So as to provide you with ease and enlarge our business, we even have inspectors in QC Crew and guarantee you our best company and solution for China Factory for Dengue Iggigm Rapid Test Strip - Diagnostic Kit for Procalcitonin – Baysen , The product will supply to all over the world, such as: Algeria, Jeddah, Argentina, After years of development, we have formed strong ability in new product development and strict quality control system to ensure excellent quality and service. With the support of many long term cooperated customers, our products are welcomed all over the world.
By Linda from Norwegian - 2016.11.01 17:04
The factory workers have rich industry knowledge and operational experience, we learned a lot in working with them,we are extremely grateful that we can encount a good company has excellent wokers.
By Eden from Lesotho - 2015.06.26 19:27