CE approved blood type ABD rapid test kit Solid phase
Solid Phase
Production information
Model Number | ABD blood type | Packing | 25 Tests/ kit, 30kits/CTN |
Name | Blood type ABD Rapid Test | Instrument classification | Class I |
Features | High sensitivity, Easy opeation | Certificate | CE/ ISO13485 |
Accuracy | > 99% | Shelf life | Two Years |
Methodology | Colloidal Gold | OEM/ODM service | Avaliable |
Test procedure
1 | Before using the reagent,read the package insert carefully and familiarize yourself with the operating procedures. |
2 |
In case of thin stool of patients with diarrhea, use disposable pipette to pipette sample, and add 3 drops (approx.100μL) of sample dropwise to sampling tube, and thoroughly shake sample and sample diluent for later use.
|
3 |
Remove test device from aluminum foil pouch, lie it on a horizontal workbench, and do a good job in marking.
|
4 | Using a capillary burette,add 1 drop(approximately 10ul) of the sample to be tested to each well of A,B and D respectively. |
5 | After the sample has been added,add 4 drops(approximately 200ul) of sample rinse to the diluent wells and start timing. After the sample has been added,add 4 drops(approximately 200ul) of sample rinse to the diluent wells and start timing. |
6 | After the sample has been added,add 4 drops(approximately 200ul) of sample rinse to the diluent wells and start timing. |
7 | Visual interpretation can be used in result interpretation. Visual interpretation can be used in result interpretation. Visual interpretation can be used in result interpretation. |
Note: each sample shall be pipetted by clean disposable pipette to avoid cross contamination.
Background Knowledge
Human red blood cell antigens are classified into several blood group systems according to their nature and genetic relevance.Some blood with other blood types are incompatible with other blood types and the only way to save a patient's life during a blood transfusion is to give the recipient the right blood from the donor. Transfusions with incompatible blood types may result in life-threatening hemolytic transfusion reactions.The ABO blood group system is the most important clinical guiding blood group system for organ trsnsplantation,and the RH blood group typing system is another blood group system second only to the ABO blood group in clinical transfusion-related,pregnancies with mother-child Rh blood incompatibility are at risk of neonatal hemolytic disease,and screening for ABO and Rh Blood groups has been made routine.
Superiority
Testing time:10-15mins
Storage:2-30℃/36-86℉
Methodology:Solid Phase
Feature:
• High sensitive
• result reading in 15 minutes
• Easy operation
• Do not need extra machine for result reading
Result reading
The WIZ BIOTECH reagent test will be compared with the control reagent:
Test result of wiz | Test result of reference reagents | Positive coincidence rate:98.54%(95%C.I.94.83%~99.60%) Negative coincidence rate:100%(95%C.I.97.31%~100%)Total compliance rate:99.28%(95%C.I.97.40%~99.80%) | ||
Positive | Negative | Total | ||
Positive | 135 | 0 | 135 | |
Negative | 2 | 139 | 141 | |
Total | 137 | 139 | 276 |