We now have our individual sales group, layout team, technical team, QC crew and package group. Now we have strict high-quality control procedures for each procedure. Also, all of our workers are experienced in printing discipline for Elisa Test , Renal Function Test Kit , Dengue Mosquito , We just not only provide the high quality to our customers, but more even important is our best service and the competitive price.
100% Original Helicobacter Pylori Diagnosis - Diagnostic Kit for Antibody to Helicobacter Pylori(Fluorescence Immunochromatographic Assay) – Baysen Detail:

Diagnostic Kit for Antibody to Helicobacter Pylori(Fluorescence Immunochromatographic Assay)
For in vitro diagnostic use only

Please read this package insert carefully prior to use and strictly follow the instructions. Reliability of assay results cannot be guaranteed if there are any deviations from the instructions in this package insert.

INTENDED USE
Diagnostic Kit for Antibody to Helicobacter Pylori (Fluorescence Immunochromatographic Assay)is a fluorescence immunochromatographic assay for the quantitative detection of HP antibody in human serum or plasma. which is important auxiliary diagnostic value for gastric infections.All positive sample must be confirmed by other methodologies. This test is intended for healthcare professional use only.

SUMMARY
Gastric helicobacter pylori infection is closely related with chronic gastritis, gastric ulcer, gastric adenocarcinoma, gastric mucosa associated lymphoma, H.p ylori infection rate of about 90% in gastritis, gastric ulcer, duodenal ulcer and gastric cancer patients. WHO has identified h. pylori as the first type of cancer-causing factor.it is a risk factor for gastric cancer.H.pylori detection is of great value in the diagnosis of h. pylori infection.

PRINCIPLE OF THE PROCEDURE
The membrane of the test device is coated with HP antigen on the test region and goat anti rabbit IgG antibody on the control region. Lable pad are coated by fluorescence labeled HP antigen and rabbit IgG in advance. When testing positive sample, the HP antibody in sample combine with fluorescence labeled HP antigen, and form immune mixture. Under the action of the immunochromatography, the complex flow in the direction of absorbent paper, when complex passed the test region, it combined with HP coating antigen, forms new complex.HP-Ab level is positively correlated with fluorescence signal, and the concentration of HP-Ab in sample can be detected by fluorescence immunoassay assay

REAGENTS AND MATERIALS SUPPLIED

25T package components
Test card individually foil pouched with a desiccant 25T
Sample diluents 25T
Package insert 1

MATERIALS REQUIRED BUT NOT PROVIDED
Sample collection container,timer

SAMPLE COLLECTION AND STORAGE
1.The samples tested can be serum, heparin anticoagulant plasma or EDTA anticoagulant plasma.

2.According to standard techniques collect sample. Serum or plasma sample can be kept refrigerated at 2-8℃ for 7days and cryopreservation below -15°C for 6 months.
3.All sample avoid freeze-thaw cycles.

ASSAY PROCEDURE
Please read the instrument operation manual and package insert before testing.

1.Lay aside all reagents and samples to room temperature.
2.Open the Portable Immune Analyzer(WIZ-A101), enter the account password login according to the operation method of the instrument, and enter the detection interface.
3.Scan the dentification code to confirm the test item.
4.Take out the test card from the foil bag.
5.Insert the test card into the card slot, scan the QR code, and determine the test item.
6.Add 20μL serum or plasma sample to sample diluent, and mix well..
7.Add 80μL sample solution to sample well of the card.
8.Click the “standard test” button, after 15 minutes, the instrument will automatically detect the test card, it can read the results from the display screen of the instrument, and record/print the test results.
9.Refer to the instruction of Portable Immune Analyzer(WIZ-A101).

EXPECTED VALUES
HP-Ab<10

It is recommended that each laboratory establish its own normal range representing its patient population.

TEST RESULTS AND INTERPRETATION
.The above data is the result of HP-Ab reagent test, and it is suggested that each laboratory should establish a range of HP-Ab detection values suitable for the population in this region. The above results are for reference only.

.The results of this method are only applicable to the reference ranges established in this method, and there is no direct comparability with other methods.
.Other factors can also cause errors in detection results, including technical reasons, operational errors and other sample factors.

STORAGE AND STABILITY
1.The kit is 18 months shelf-life from the date of manufacture. Store the unused kits at 2-30°C. DO NOT FREEZE. Do not use beyond the expiration date.

2.Do not open the sealed pouch until you are ready to perform a test, and the single-use test is suggested to be used under the required environment (temperature 2-35℃, humidity 40-90%) within 60 mins as quickly as possible.
3.Sample diluent is used immediately after being opened.

WARNINGS AND PRECAUTIONS
.The kit should be sealed and protected against moisture.

.All positive specimens shall be validated by other methodologies.
.All specimens shall be treated as potential pollutant.
.DO NOT use expired reagent.
.DO NOT interchange reagents among kits with different lot No..
.DO NOT reuse test cards and any disposable accessories.
.Misoperation, excessive or little sample can lead to result deviations.

LIMITATION
.As with any assay employing mouse antibodies, the possibility exists for interference by human anti-mouse antibodies (HAMA) in the specimen. Specimens from patients who have received preparations of monoclonal antibodies for diagnosis or therapy may contain HAMA. Such specimens may cause false positive or false negative results.

.This test result is only for clinical reference, should not serve as the only basis for clinical diagnosis and treatment, the patients clinical management should be comprehensive consideration combined with its symptoms, medical history, other laboratory examination, treatment response, epidemiology and other information.
.This reagent is only used for serum and plasma tests. It may not obtain accurate result when used for other samples such as saliva and urine and etc.

PERFORMANCE CHARACTERISTICS

Linearity 10-1000 relative deviation:-15% to +15%.
Linear correlation coefficient:(r)≥0.9900
Accuracy The recovery rate shall be within 85% – 115%.
Repeatability CV≤15%

REFERENCES
1.Shao,J.L.&F.Wu.Recent advances in the detection methods of Helicobacter pylori[J].Journal of Gastroenterology and Hepatology,2012,21(8):691-694

2.Hansen JH,et al.HAMA Interference with Murine Monoclonal Antibody-Based Immunoassays[J].J of Clin Immunoassay,1993,16:294-299.
3.Levinson SS.The Nature of Heterophilic Antibodies and the Role in Immunoassay Interference[J].J of Clin Immunoassay,1992,15:108-114.
Key to symbols used:

 t11-1 In Vitro Diagnostic Medical Device
 tt-2 Manufacturer
 tt-71 Store at 2-30℃
 tt-3 Expiration Date
 tt-4 Do Not Reuse
 tt-5 CAUTION
 tt-6 Consult Instructions For Use

Xiamen Wiz Biotech CO.,LTD
Address:3-4 Floor,NO.16 Building,Bio-medical Workshop,2030 Wengjiao West Road,Haicang District,361026,Xiamen,China
Tel:+86-592-6808278
Fax:+86-592-6808279


Product detail pictures:

100% Original Helicobacter Pylori Diagnosis - Diagnostic Kit for Antibody to Helicobacter Pylori(Fluorescence Immunochromatographic Assay) – Baysen detail pictures

100% Original Helicobacter Pylori Diagnosis - Diagnostic Kit for Antibody to Helicobacter Pylori(Fluorescence Immunochromatographic Assay) – Baysen detail pictures


Related Product Guide:
PSA Test Market Research With Industry Segments, Characteristics and Size With Forecast By 2023 | Psa Test Cost
Ces études à la con qui nous prennent pour des connes | P24 Test Strips

Now we have highly developed devices. Our items are exported towards the USA, the UK and so on, enjoying a great popularity among the customers for 100% Original Helicobacter Pylori Diagnosis - Diagnostic Kit for Antibody to Helicobacter Pylori(Fluorescence Immunochromatographic Assay) – Baysen , The product will supply to all over the world, such as: Argentina, Vietnam, Costa rica, We focus on providing service for our clients as a key element in strengthening our long-term relationships. Our continual availability of high grade products in combination with our excellent pre-sale and after-sales service ensures strong competitiveness in an increasingly globalized market. We are willing to cooperate with business friends from at home and abroad and create a great future together.
  • As an international trading company, we have numerous partners, but about your company, I just want to say, you are really good, wide range, good quality, reasonable prices, warm and thoughtful service, advanced technology and equipment and workers have professional training, feedback and product update is timely, in short, this is a very pleasant cooperation, and we look forward to the next cooperation!
    5 Stars By Dorothy from Sweden - 2016.06.16 18:23
    The company has a good reputation in this industry, and finally it tured out that choose them is a good choice.
    5 Stars By Evangeline from Finland - 2016.05.02 18:28