100% Original Factory Occasional Doa Use Drug Test - colloidal gold transferrin tf rapid test home use selftest kit POCT reagent – Baysen

short description:


Product Detail

Product Tags

Related Video

Feedback (2)

Our enhancement depends around the sophisticated devices ,exceptional talents and repeatedly strengthened technology forces for D-Dimer Test Kit , Diagnositc Kit For Follicle Stimulating Hormone , Dengue Rapid Test Kit , Make sure you come to feel absolutely cost-free to speak to us for organization. nd we think we're going to share the ideal trading practical experience with all our retailers.
100% Original Factory Occasional Doa Use Drug Test - colloidal gold transferrin tf rapid test home use selftest kit POCT reagent – Baysen Detail:

Products Parameters

3.TF-2

PRINCIPLE AND PROCEDURE OF FOB TEST

PRINCIPLE

The membrane of the test device is coated with Tf antibody on the test region and goat anti rabbit IgG antibody on the control region. Lable pad are coated by fluorescence labeled anti Tf antibody and rabbit IgG in advance. When testing positive sample, the Tf antigen in sample combine with fluorescence labeled anti Tf antibody, and form immune mixture. Under the action of the immunochromatography, the complex flow in the direction of absorbent paper. When complex passed the test region, it combined with anti Tf coating antibody, forms new complex.

If it is negative, the sample does not contain transferrin or the content is low, so that the immune complex cannot be formed. There will be no red line in the detection area (T). No matter whether Tf antibody exists in the specimen or not, the remaining colloidal gold-labeled mouse anti-human IgM monoclonal antibody and the goat anti-mouse IgG antibody coated in the quality control area (C) line. Then the agglutinates develop color in the quality control area, and the red line will appear in (C). The red line is the standard appears in the quality control area (C) for judging whether there are enough samples and whether the chromatography process is normal. It is also used as an internal control standard for reagents.

Test Procedure

Please read the package insert before testing.

1.Take out the test card from the foil bag, put it on the level table and mark it.

2.Remove the cap from the sample tube and discard the first two drops diluted sample, add 3 drops (about 100uL) no bubble diluted sample vertically and slowly into sample well of the card with provided dispette. Then start the timer.

packing

You May like


Home used SARS-CoV-2 Antigen Rapid Test(Colloidal Gold)


SARS-CoV-2 Antigen Rapid Test(Colloidal Gold)


WIZ-A101 Portable Immune Analyzer


WIZ-A101 Portable Immune Analyzer


6.超级链接产品第三个产品的图片cal


Diagnostic Kit for calprotectin (Colloidal Gold)

About Us

贝尔森主图_conew1

Xiamen Baysen Medical Tech limited is a high biological enterprise which devotes itself to filed of fast diagnostic reagent and integrates research and development, production and sales into a whole. There are many advanced research staffs and sales managers in the company, all of them are have rich working experience in china and international biopharmaceutical enterprise.

Certificate display

dxgrd


Product detail pictures:

100% Original Factory Occasional Doa Use Drug Test - colloidal gold transferrin tf rapid test home use selftest kit POCT reagent – Baysen detail pictures

100% Original Factory Occasional Doa Use Drug Test - colloidal gold transferrin tf rapid test home use selftest kit POCT reagent – Baysen detail pictures

100% Original Factory Occasional Doa Use Drug Test - colloidal gold transferrin tf rapid test home use selftest kit POCT reagent – Baysen detail pictures

100% Original Factory Occasional Doa Use Drug Test - colloidal gold transferrin tf rapid test home use selftest kit POCT reagent – Baysen detail pictures

100% Original Factory Occasional Doa Use Drug Test - colloidal gold transferrin tf rapid test home use selftest kit POCT reagent – Baysen detail pictures


Related Product Guide:
Benefits of PSA test to screen for prostate cancer are roughly equal to its harms, expert panel says | P24 Test Strips
Myeloid-related protein 8 induces self-tolerance and cross-tolerance to bacterial infection via TLR4- and TLR2-mediated signal pathways | Psa Test Cost

Our rewards are lower costs,dynamic profits team,specialised QC,potent factories,high-quality services for 100% Original Factory Occasional Doa Use Drug Test - colloidal gold transferrin tf rapid test home use selftest kit POCT reagent – Baysen , The product will supply to all over the world, such as: Hamburg, Bulgaria, Jordan, "Good quality, Good service " is always our tenet and credo. We take every effort to control the quality, package, labels etc and our QC will check every detail during producing and before shipment. We are willing to establish long business relationship with those who seek the high quality products and good service. We have set up a wide sales network across European countries, North of America, South of America, Middle East, Africa, East Asia countries.Please contact us now, you will find our professional experience and high quality grades will contribute to your business.
  • We have been looking for a professional and responsible supplier, and now we find it.
    5 Stars By Lee from Rome - 2016.11.12 12:31
    This manufacturer can keep improving and perfecting products and service, it is in line with the rules of market competition, a competitive company.
    5 Stars By Helen from Australia - 2015.06.18 17:25